Chapter 4 Installation
Gen 3 Site Controller System Manual
Intercabling Connections
4-8
68P80801E30-A 5/1/2002
Junction Panels
Most of the intercabling is accomplished on the junction panel located at the
top-rear of the equipment cabinet. Figure 4-2 shows the junction panel.
The junction panel is accessed from the rear of the cabinet. All intercabinet
cabling runs up and out the top of each cabinet into the cable tray assembly.
The OUT connection for each cable has been connected by the factory.
Installation of intercabinet cabling is completed by connecting the free end
of each cable into the appropriate IN connector of adjacent cabinets.
Cavity Combining RFDS Intercabinet Cabling
Intercabling between the Control Cabinet and the RF Cabinets for systems
equipped with Cavity Combining RF Distribution Systems is listed below.
Choose the appropriate table below, then refer to the appropriate instructions
for connecting the required intercabling.
1-5 Channel Omni Site Cables
Table 4-1 lists the required cables for an omni site (single sector).
EBTS315
032801JNM
GPS B
GPS A
OUT 3
OUT 2
OUT 1
10B2-3
10B2-2
10B2-1
TX OUT
RX2
RX3
RX1
5MHz/1PPS
ETHERNET
SITE GROUND
SITE GROUND
NOTE:
Three additional groud studs are used for SRRC, SRSC, and 23” Racks.
Figure 4-2
Site Controller junction panel (rear view)
Table 4-1
1-5 Channel Omni Site Intercabling
Cable PN
Description
Qty.
Connection
0112004Z29
Ethernet
1
Site controller
to RF Cabinet #1
0112004Z29
5 MHz/1 PPS
1
Site controller
to RF Cabinet #1
3084225N42
Alarms
1
EAS/EAS2 to RF Cabinet #1
3082070X01
PCCH
Redundancy
1
Site controller
to RF Cabinet #1