68P80801E30-A 5/1/2002
3-7
Gen 3 Site Controller System Manual
Chapter 3 Pre-Installation
Site Planning
Note:
The DC power wires provided are suitable for routing within a single
equipment rack or cabinet. They should not be used to connect to a
power source external to the equipment rack that houses the Site
Controllers and EAS/EAS2. If your installation requires a sourcing
power from an external supply, use appropriate wiring and
installation in strict accordance with the National Electrical Code
NFPA 70 or the applicable codes and regulations for your site.
10-32 OR 12-24 SCREWS
MAIN BRACKET
(QTY 2)
M4 SCREWS
(QTY 12)
ATTACH GROUND
BRACKET FOR STATIC
STRAP WHERE NEEDED
M6 ZINC PLATED
STEEL SCREWS
(QTY 4)
JUNCTION PANEL
ISC300
050401JNM
ANGLE BRACKET
(QTY 4)
M10 NUT FOR
JUNCTION PANEL
GROUND STUD
(QTY 2)
M6 NUT FOR
JUNCTION PANEL
GROUND STUD
(QTY 3)
M6 BLACK SCREWS
1U BLANK PANEL
(QTY 2)
Figure 3-2
Assembly for mounting on a 3 to 6 inch deep rack