Appendix B Parts & Suppliers
Gen 3 Site Controller System Manual
B-8
68P80801E30-A 5/1/2002
Site alarm wiring
The following table identifies recommended Motorola part numbers for
prewiring the site alarms.
Cabinet mounting hardware
The cabinet mounting hardware is site dependent and must be procured
locally.
Equipment cabinets
The mounting hardware used to secure the equipment cabinets containing
control and/or RF hardware must be able to provide 1545 pounds of
retention force.
■
If the cabinets are to be secured to a concrete floor, 1/2” grade 8 bolts with
anchors are recommended.
■
If the cabinets are to be secured to another type of floor, determine the
appropriate mounting hardware.
Power Supply Rack
The Motorola offered Power Supply Rack from Power Conversion Products
is available in a standard and an earthquake rack.
Power Conversion Products, Inc.
42 East Street
P.O. Box 380
Crystal Lake, IL 60014
Phone:
815 459-9100
Phone:
800 435-4872 (customer service)
Fax:
815 459-9118
If the earthquake rack is used, it must be bolted to the floor using the
02100-13 High Performance Anchor Kit
, consisting of:
Part number
Description
Quantity
0183652P01
punch block
2
3083892X04
alarm cable for
EAS
2
3083892X07
alarm cable for
EAS2
2