Troubleshooting: General Check of a Site Controller File
Chapter 13: MTS Troubleshooting
Troubleshooting: General Check of a Site Controller File
To check the validity of a particular
fi
le in the Flash Filing System of the Site Controller, it is
necessary to use both the
ls
command and the
attrib
command as follows.
This example looks at the con
fi
guration
fi
le of the Site Controller.
Using the ls command
fi
rst ensures that the information shared between ls and attrib is synchronised.
1.
Use the
ls
command to produce a listing of all
fi
les on the Site Controller. There is no wildcard
option with ls. Check the
fi
les of interest that do not have any warning after their details. This
shows only a small part of the typical output.
reg.dat.bk1 0 - not set- 000000 00000000 (bad header)
tsc.cf.1.bk1 11635 - not set- 000000 2dbb8018
tsc.cf.2.bk1 0 - not set- 000000 00000000 (bad header)
In this example tsc.cf.1 looks like a valid
fi
le, whilst tsc.cf.2 has a bad header warning
so it can’t be valid. The ‘.bk1’ indicates that the
fi
le is back-up copy 1.
2.
Use command
attrib tsc.cf*
to produce a listing of the con
fi
guration
fi
les attributes of the Site
Controller.
SC: attrib tsc.cf*
ATTRIB NAME VERSION DATE
----------------------------------------------------
----r- tsc.cf pr3swdl 20/02/2003_18:39:33
cn--r- tsc.cf.1 pr3swdl 20/02/2003_18:39:33
---w-a tsc.cf.2 - -
Note which
fi
le has the ‘c’ (Current) attribute and ensure that:
◦
It also has the ‘r’ (read) attribute. If the
fi
le has the w (write) attribute, it is not valid.
◦
Also check the generic
fi
le title (‘tsc.cf’ in this case) shares the
same version and date information.
If there is no valid
fi
le then this should be downloaded to the Site Controller again, using
either Dimetra BTS Service Software or Software Download (SWDL.)
13-8
6802800U74-N September 2009
Содержание DIMETRA MTS 2
Страница 4: ...This page intentionally left blank ...
Страница 28: ...List of Procedures This page intentionally left blank xxii 6802800U74 N September 2009 ...
Страница 30: ...List of Processes This page intentionally left blank xxiv 6802800U74 N September 2009 ...
Страница 46: ...Cooling Fans Chapter 1 MTS Overview This page intentionally left blank 1 12 6802800U74 N September 2009 ...
Страница 52: ...Battery Safety Chapter 2 General Safety This page intentionally left blank 2 6 6802800U74 N September 2009 ...
Страница 146: ...Screws Chapter 4 Hardware Installation Figure 4 59 MTS 4 Screws Positions 4 70 6802800U74 N September 2009 ...
Страница 148: ...Screws Chapter 4 Hardware Installation This page intentionally left blank 4 72 6802800U74 N September 2009 ...
Страница 348: ...Base Radio Restoration Chapter 10 Base Radio This page intentionally left blank 10 12 6802800U74 N September 2009 ...
Страница 360: ...PSU TrackID Update Chapter 11 Power Supply Unit This page intentionally left blank 11 12 6802800U74 N September 2009 ...
Страница 474: ...Configuration Chapter 15 Expansion Options This page intentionally left blank 15 44 6802800U74 N September 2009 ...
Страница 476: ...Introduction Chapter 16 MTS 4 Outdoor Enclosure This page intentionally left blank 16 2 6802800U74 N September 2009 ...
Страница 486: ...This page intentionally left blank A 10 6802800U74 N September 2009 ...
Страница 492: ...This page intentionally left blank B 6 6802800U74 N September 2009 ...
Страница 496: ...This page intentionally left blank C 4 6802800U74 N September 2009 ...