Release 1.0
Configuring the CMTS
526360-001-00 Rev. B
MGBI
6-33
■
Storing FFT Power Level Measurement Data
■
Displaying FFT Power Level Measurement Data
Configuring FFT
The
fft setup
command can be used to configure the FFT processor on the BCM3138/
BCM3140 chip set or to display the current FFT processor configuration.
Configuring the FFT Processor
Use the
fft setup
command, in Privileged EXEC mode, to configure the FFT
processor, as follows:
MOT#
fft setup
<
Slot
/
Port>
[
sample
{<
256
-
2048
>}
mode
{
Tap-in
}
window
{
blackman
|
blackman-harris
|
hamming
|
hanning
|
rectangular
}]
where:
Slot
is always 0 for the BSR 2000.
Port
is a valid upstream port number.
sample
256
-
2048
is the number of samples of the power level measurement. The
default is 2048.
mode Tap-in
is the
RF Sentry’s operational mode
window
is the window coefficient to shape the output of the power level
measurement (
rectangular
,
hamming
,
hanning
,
blackman
, or
blackman-harris
). The default is
rectangular
.
Displaying the FFT Processor Configuration
Use the
fft setu
p <
Slot
/
Port>
command, without any additional arguments, to display
the current FFT processor configuration for a particular port on a particular CMTS
module, as follows:.
MOT#
fft setup
<
Slot
/
Port>
where:
Slot
is always 0 for the BSR 2000.
Port
is a valid upstream port number.
Содержание BSR 2000
Страница 1: ...BSR 2000 Configuration and Management Guide 526360 001 00 Rev B Release 1 0 MGBI ...
Страница 6: ... Motorola Motorola Motorola Motorola Motorola Motorola Motorola Motorola Motorola ...
Страница 50: ......
Страница 130: ......
Страница 164: ......
Страница 458: ......
Страница 490: ......
Страница 580: ......
Страница 632: ......
Страница 648: ......
Страница 649: ......
Страница 650: ...526360 001 00 Rev B 7 06 MGBI Visit our website at www motorola com ...