Motorola solutions avigilon HD-NVR4-STD-16TB Скачать руководство пользователя страница 16

Total record time estimate is based on constant recording

The retention time is determined by the

Max. Record Time

setting and the average camera data rate. Since the

system can only provide an estimate of the data rate for the full retention period, the actual retention time may
exceed the Max. Record Time setting by 5 minutes.

NOTE:

The time shown in the Total Record Time column is an estimate only.

1. In the server Setup tab, click

.

The Recording and Bandwidth dialog box is displayed.

The Data Aging column shows an estimate of the recording time that is available at each image rate,
given the amount of space on the recording device.

2. In the Data Aging column, move the sliders to adjust the amount of time video is stored at each image

rate.

l

To change the data aging settings for all linked cameras, move the slider for one linked camera
and all linked cameras will be updated.

l

To change the data aging setting for one camera, break the camera's link to other cameras by
clicking the

icon to the left of its name, then make your changes.

3. In the

Max. Record Time

column, manually enter a maximum record time or select one of the options from

the drop-down list for each camera.

NOTE:

If the time estimated in the Total Record Time column is significantly shorter than what is set in the

Max. Record Time column, the camera's actual recording time will be closer to the Total Record Time
estimate.

4. Click

OK

.

Adding Users and Groups

If there will be other people using the system, you may want to add them as separate users rather than giving
them access through the default administrator account.

Before you can add individual users, you will need to add permission groups that define what users have access
to. By default, the system has the following groups:

l

Administrators

— has access to everything in the system.

l

Power Users

— has access to most features in the system except for the ability to import and export

settings.

l

Restricted Users

— has access to live video only and can control audio and digital outputs.

l

Standard Users

— has access to live and recorded video, but cannot make any Setup changes.

It is highly recommended that the Administrators group includes at least two users. In the event one
administrator user forgets the default administrator password, the second administrator user can be used to
reset the password. If you do not have a second administrator user, you may need to completely reset the
system.

Adding Users and Groups

12

Содержание avigilon HD-NVR4-STD-16TB

Страница 1: ...Installation Guide Avigilon HD Network Video Recorder HD NVR4 STD 16TB HD NVR4 STD 24TB HD NVR4 STD 32TB and HD NVR4 STD 48TB...

Страница 2: ...demark patent or other intellectual property rights of Avigilon Corporation or its licensors This document has been compiled and published using product descriptions and specifications available at th...

Страница 3: ...ware 6 Networking 6 Configuring the Avigilon Control Center Software 7 Starting Up and Shutting Down the Avigilon Control Center Client Software 7 Starting Up the Client Software 7 Shutting Down the C...

Страница 4: ...lacing a Hard Drive Blank 16 Replacing Front or Back Hard Drives 18 LED Indicators 19 Diagnostic Indicators 19 Power Status Indicators 19 Network Link Status Indicators 20 Hard Drive RAID Status Indic...

Страница 5: ...site Overview Front View 1 Bezel Protects against unauthorized physical access to the hard drives 2 Power button Controls the power supply to the recorder 3 Hard drives Provides access to hot swappab...

Страница 6: ...Accepts an OOBM RJ 45 connection 2 Serial connector Accepts connections to serial devices 3 Video connector Accepts a VGA monitor connection 4 USB connectors Accepts USB connections to external devic...

Страница 7: ...Connecting Cables Refer to the diagrams in the Overview section for the location of the different connectors Make the following connections as required 1 Connect a KVM switch or separate keyboard mou...

Страница 8: ...4 Set a password for the user name you entered on the previous screen When you are ready click Next 5 Once logged in the recorder will go through initial system setup 6 The Setup dialog will start co...

Страница 9: ...s to log in dialog box is displayed If you are connected only to the new recorder one site is listed in the left navigation panel The default name is HDVA 3 Double click the new recorder name to log i...

Страница 10: ...remove deactivate and reactivate licenses for the ACC 6 software For more information see the Avigilon Control Center Client User Guide Downgrading to the ACC 5 Software 1 Open Windows Settings Apps F...

Страница 11: ...trol Center Client l Double click or desktop shortcut icon When you are prompted log in to your site You can only access cameras and video after you log in Once the application has started it will aut...

Страница 12: ...twork authentication protocol Contact your network administrator for help 4 Click Log In You are logged into the selected sites If you want to be notified when new or disconnected sites come online se...

Страница 13: ...ick The Connect Disconnect Devices tab is displayed 2 In the Discovered Devices area select one or more devices then click Connect Tip You can also drag the device to a server on the Connected Devices...

Страница 14: ...this procedure if you prefer to keep the default settings Before you can assign a recording schedule you must create a template The template allows you to assign the same schedule to multiple cameras...

Страница 15: ...how long the full image rate video is kept so that you have the best quality video when you need it The amount of data aging that is available depends on the camera you have connected to your system...

Страница 16: ...of the options from the drop down list for each camera NOTE If the time estimated in the Total Record Time column is significantly shorter than what is set in the Max Record Time column the camera s a...

Страница 17: ...users do not have difficulty choosing new passwords d Select the required Group Privileges and Access Rights for the group Clear the check box of any feature or device that you do not want the group t...

Страница 18: ...of the password The strength is defined by the group the user is assigned to If the user is a member of more than one group the user must meet the strongest password requirement The password must meet...

Страница 19: ...vents dialog box to configure classified object motion detection or UMD Once configured you can receive events trigger alarms define rules and record video when classified object motion requires your...

Страница 20: ...he Windows software administrator username and password that was configured for the recorder 3 On the Server Administrator home page the health of the system components are displayed in the workspace...

Страница 21: ...place the blanks with hard drives as required 1 Remove the bezel a Unlock the bezel b Push the release button next to the lock c Pull the left end of the bezel then unhook the right end to remove the...

Страница 22: ...is not displayed in the Server Administrator try one of the following l Refresh the browser l Reboot the recorder Replacing Front or Back Hard Drives 1 Locate the failed hard drive at the front or ba...

Страница 23: ...t blocked Electrical l Blinks orange the recorder is experiencing an electrical error Errors include l voltage out of range l failed power supply l voltage regulator Check the power status indicator t...

Страница 24: ...corder s connection status LEDs above the Ethernet port display the recorder s connection status to the network The following table describes what the LEDs indicate Figure 3 1 Link LED 2 Connection ac...

Страница 25: ...ive is online Off The hard drive is disconnected from the recorder Two short green flashes every second The system is identifying a new hard drive or preparing a hard drive for removal Flashes green o...

Страница 26: ...VAC 50 60 Hz auto switching Power Consumption Average 270 W 921 3 BTU h Maxmium 750 W 2560 8 BTU h Power Supply 750 W single optional secondary power supply Environmental Operating Temperature 10 C to...

Страница 27: ...ue 6 EN 55032 2012 EN 55032 2015 CISPR 32 2012 CISPR 32 2015 Class A EN 61000 3 2 2014 IEC 61000 3 2 2014 Class D EN 61000 3 3 2013 IEC 61000 3 3 2013 Electromagnetic Immunity EN 55024 2010 A1 2015 CI...

Отзывы: