background image

4A

4B

24V

1

1

1

1

1

2

2

2

2

2

3

3

3

3

4

4

4

4

5

5

5

5

6

7

8

9

CN1

CN2

CN3

CN4

CN5

Dipper

LS LO FO

LA

FC

LE

3A

3B

EN

EN

CN4

01

 • Safety Edge

02

 • Photocells

03

 • Encoder (not used)

04

 • Encoder (not used)

05

 • Common

CN5

01

 • +24V DC Auxiliary Power Supply for LED RGB flashing light

02

 • Y output

03

 • R output

04

 • G output

05

 • B output

LS

 • LED lit when the pedestrian push button is active 

LO

 • LED lit when the total push button is active

F0

 • LED off when the opening limit switch is active

FC

 • LED off when the closing limit switch is active

LA

 • LED off when safety edge is active (when 

P6

 is active)

LE

 • LED off when photocells are active (when 

P5

 is active)

Courtesy light or flashing light:

08 

and

 09

 • This output allows connection of a courtesy light or a flashing light

(see 

P8

 in page 11B).

Limit switches:

03

 and 

04

 • The control board needs a opening and closing limit-switches 

connection (both in NC). Triggering any limit-switch will make the immediate 

stoppage of the movement.

The limit-switch thriggering is visible on the display. OP (opening limit switch 

activated) and CL (opening limit switch activated).

It is mandatory the use of limit switches.

Safety circuits:

01

 • This input allows connection of safety bands. The device operates according 

to programming set in the 

P6 

menu

 

(

page 10B

)

02

 • This input allows connection of photocells. The device operates according 

to programming set in the 

P5 

menu

 

(

página 10A

)

Shunt application is not necessary.

01

 • Auxiliary output for flashing light or 24V DC LED.

Open collector for the management of auxiliary functions:

02

 • The Y output is activated in intermittent mode, only with the closed gate.

03

 • The R output is activated in intermittent mode, only in closing phase.

04

 • The G output is activated in intermittent mode, only in opening phase.

05

 • The B output is activated in intermittent mode, only in pause time.

The dipper indicates which motor is connected to the control board.

CN1

LED

s

CN2

CN4

CN5

Dipper

Put the dipper in 

this position when 

using motors with 

power < 500 watts

Put the dipper in this 

position when using 

motors with power >  

500 watts

PROGRAMMING PRE-RECOMENDATIONS

02. THE CONTROL BOARD

02. THE CONTROL BOARD

TECHNICAL SPECIFICATIONS

To enhance knowledge about the control board operation, before proceeding to the 

setup, give special attention to the instructions that follow.

PROGRAMMING PRE-RECOMENDATIONS

02.  THE CONTROL BOARD

Содержание MC50SC

Страница 1: ...24V 1 2 v7 2 REV 03 2021 EN USER INSTALLER MANUAL MC50SC...

Страница 2: ...P0 AUTOMATIC PROGRAMMING OF THE COURSE E2 COURTESY LIGHT TIME P6 SAFETY BAND P3 PEDESTRIAN COURSE TIME E6 DECELERATION SPEED P9 DISTANCE PROGRAMMING P1 SETTING THE DECELERATION TIME E3 FOLLOW ME P7 OP...

Страница 3: ...not make any changes to the automation components and or their accessories Control board for indoor use with 230V connection Keep remote controls away from children to prevent the automated system fro...

Страница 4: ...vated It is mandatory the use of limit switches Safety circuits 01 This input allows connection of safety bands The device operates according to programming set in the P6 menu page 10B 02 This input a...

Страница 5: ...s not match the gate s movement turn off the control board from the power supply e swap the 5 and 7 wires from CN1 and check if it is correct with 3 and 4 from CN2 ESSENTIAL STEPS FOR INSTALLATION 03...

Страница 6: ...cells in opening 00 00 10A Safety band Security Band Disabled Security Band Activated 8k2 input NC input Band in closure Band in opening 00 01 00 10B OperatiNG logic Automatic mode function Step by st...

Страница 7: ...seconds 02 P0 appears Press MENU for 1 second 04 When MA appears press MENU for 1 second The motor will start a slow closing of the door 05 When it reach the closing limit switch it will open automati...

Страница 8: ...vement inertia which could cause it to get stuck factory default 3 min max 0s 03 P1 appears Press MENU for 1 second 04 tP appears Press MENU for 1 second 06 Press MENU for 1 second to save the set val...

Страница 9: ...P If you set the sensitivity FS to a value greater than 1 the force FO is automatically set to 9 without the possibility to change it Note If the control board has very high sensitivity values you ma...

Страница 10: ...defined time Pause time adjustment of the total closure Allows you to set the time that the gate will remain open Pause time adjustment of the pedestrian closure Allows you to set the time that the ga...

Страница 11: ...ault 00 02 P0 appears Press five times 02 P0 appears Press six times 03 P5 appears Press MENU for 1 second 03 P6 appears Press MENU for 1 second 04 HE appears Press MENU for 1 second 01 Press MENU for...

Страница 12: ...or control board start button factory default 00 02 P0 appears Press seven times 01 Press MENU for 3 seconds 03 P7 appears Press MENU for 1 second 05 Press MENU to save the defined function 04 Appear...

Страница 13: ...viously stored transmitter memorize transmitters page 5B Factory default 00 Distance programming operation PGM ON Press the keys indicated in the picture at the same time for 10 seconds and the flashi...

Страница 14: ...ned function SOFT START 01 Press MENU for 10 seconds 02 E0 appears Press twice 03 E2 appears Press MENU for 1 second 05 Press MENU to save the defined time This menu allows you to define the time from...

Страница 15: ...es 03 E3 appears Press MENU for 1 second 05 Press MENU to save the defined function 06 E4 appears is inactive To advance to the E5 menu press once To exit the programming press simultaneously 00 disab...

Страница 16: ...maneuver it is understood by opening and closing The control board reset does not erase the maneuvers count Example 13456 maneuvers 01 Hundreds of thousands 34 Thousands 56 Dozens display flashes disp...

Страница 17: ...ds RGB OUTPUT 05 Press MENU for 1 second to save the defined function 06 E1 appears To exit the programming press simultaneously 01 Press MENU for 10 seconds 02 E0 appears Press eight times 02 E0 appe...

Страница 18: ...t switch enabled No limit switches or both open limit switches In pause time Security Band under pressure In pedestrian pause time Pedestrian button being pressed Memory full Start button being presse...

Страница 19: ...ion correctly The order of capacitor wires linked with the automatism wires are not important as long as you link one to the Brown wire and the other to the Black one The common wire of the motor must...

Страница 20: ...works the problem is from control board Pull it out and send it to our MOTORLINE technical services for diagnosis 4 If the motor doesn t work remove them from installation site and send to our MOTORL...

Страница 21: ...1 2 3 4 5 6 7 8 9 V R G B RG DV 12 24V DV 12 24V COM NC CN1 CN2 CN3 CN4 CN5 20 EN Antenna Limit switch CLOSE OPEN key selector pushbutton Pedestrian key selector pushbutton Total Safety Band or or Pho...

Отзывы: