INSTRUCTIONS

   

 

 

 

 

MODEL RF-2011 

AUTOMATIC DRAIN 

 

580 CARNEGIE STREET                                                                                                            1-800-227-2822 
MANTECA, CA 95337                                                                                                          FAX 209-239-5114    

www.motorguard.com 

 

 

 

Rev 10/13

   

33127

 

 

 

         FEATURES 

 

 

 
The Model RF-2011 Automatic Drain is designed to automatically drain your compressor tank at specified intervals.  If provides a hands-off, low 
maintenance solution to the task of tank draining which will extend the tank life, lower operating costs and improve shop air quality. 
 

FEATURES

 

 

 

Continuously Adjustable Drain and Cycle Times 

 

Installs Easily 

 

Manual Override Switch 

 

Reliable, Clog-Resistant Valve 

 

Wye Strainer Included 

 

SPECIFICATIONS

 

 

Adjustable Cycle Time: 

1-60 Min   

 

 

Adjustable Drain Time:    

1-30 Sec. 

      Max. Working Pressure:  

200 PSI 

      Max. Fluid Temperature:   

165 F 

Ambient Oper. Temperature:   35-165 F 
Enclosure:  

 

NEMA 1 

Electrical Supply:    

115V/1Ph/60Hz 

Nominal Current:    

.25 Amps 

Pipe Size:  

 

1/4 NPT         

 

         INSTALLATION

 

 

 
WARNING:  This product is intended for use in industrial compressed air systems only.  Do not install where pressures or temperatures can 
exceed those listed above. 
 
WARNING:  Completely relieve all pressure from the system before attempting to install the drain.  Disconnect compressor from all external 
sources of pressure and electrical power.  Employ approved lockout/tagout devices while working on the system.  Failure to follow these 
directions can result in serious personal injury and death. 
 

To prevent scale and debris from entering the solenoid valve, the Wye Strainer 
(4) must be installed upstream of the unit in the location indicated.  Install drain in 
proper flow direction as indicated.  A field supplied manual shutoff valve (5) may 
be installed upstream of the Wye Strainer and Drain Unit to facilitate service. 
 
For best results, the drain should be mounted at a point lower than the tank drain 
outlet and all piping should be pitched downhill to drain.  In cases where normal 
installation is not possible, the drain may be mounted at a point higher than the 
(b) the drain cycle is adjusted to account for increased volume. 
 
Connect unit to an approved, properly grounded electrical supply. 
 
 
 
 

 

Warning:  Drain should only be activated when compressor is in operation.  When the compressor is shut down, power supply to drain 
should be disconnected.  Failure to follow these directions will cause the solenoid coil to overheat and fail prematurely. 

 
Rotate the Cycle knob (1) on the front of the unit to a setting from 1 to 60 minutes.  This controls the period of time between drain activations.  Rotate the 
Drain knob (2) to a setting from 1 to 30 seconds.  This controls the period of time the drain is open for each cycle.  Observe drain operation over time 

         