The Model CO-4515 Oil Removing Filter contains a .01 micron coalescing filter element designed to remove damaging oil aerosols from the air stream.  
This filter is perfect for spray painting and other applications where oil free air is required.   

 
FEATURES

 

 

 

.01 Micron Replaceable Coalescing Filter Element 

 

Pop-Up Service Indicator Signals Need for Element Change 

 

Non-Clogging Manual Drain 

 

Highly-Visible, Ball-Float Type Sight Glass 

 

SPECIFICATIONS

 

 
    Maximum Airflow:  

 

     50 CFM 

    Operating Temperature Range:        40-160 F 
    Maximum Inlet Pressure:  

     250 PSI 

    Port Size: 

 

 

     1/2 NPT 

 

 
 
 
Before installing unit, relieve upstream pressure completely.  Install unit level with drain facing down.  Install unit in air supply line upstream of regulators 
and downstream of pre-filters.  Unit should be installed as close as possible to tools or appliances served.  Install so that airflow is in the direction 
indicated by the arrow on top of the unit.  Unit is designed for installation in a 1/2" line, use appropriate fittings for installation in other line sizes.  Apply 
pipe thread compound to male thread connections.     
 

WARNING:  This product is intended for use on industrial compressed air systems only.  It is not to be used on life support or breathing air 
systems.  Do not install where pressures or temperatures can exceed those listed above. 
 

 

 

 
 

 
 
Before pressurizing, be sure bowl is turned fully clockwise.  Pressurize slowly to avoid high-pressure surge.  
 
Inspect daily for leaks. 
 
Check level of accumulated liquid daily at sight glass (2) and drain moisture by turning drain cock (1) counter-clockwise. 
 
Check service indicator (3) regularly and replace filter when necessary. 
 
If used properly, the filter should give long, trouble free service.  The pressure drop across the filter should not exceed 10 PSI.  If the pressure drop 
exceeds 10 PSI, either the filter element needs to be replaced or the unit is being operated beyond its capacity and a larger unit is required.  Operating 
at a pressure drop of greater than 10 PSI will greatly reduce the efficiency of the filter. 
 
Installation of a 40 micron pre-filter upstream of this unit will greatly extend the life of the filter.  
 
 
 
 
 

         INSTALLATION    

 

 

         

OPERATION

     

 