Motoplat VC-014DS Скачать руководство пользователя страница 1

USER

MANUAL

www.motoplat.nl

VC-014DS

The Motoplat VC-014DS parts tester combines two devices:  
a stator winding tester and a rectifier tester.  

Once the stator is connected, the VC-014DS only take a few 
seconds to identify the phase connections and then checks 
the windings for any short circuits or connection failures. 
  
The rectifier test includes checking the circuit connections 
and measuring their operability.  

All the above mentioned data and results will appear on a 
LCD touch screen.   

This small and light weighted tester was developed 
according to the requirements of service stations and works 
without any additional testing or measuring devises. 

Stator and Rectifier Tester

ENGLISH 

VERSION 2017

Содержание VC-014DS

Страница 1: ...n checks the windings for any short circuits or connection failures The rectifier test includes checking the circuit connections and measuring their operability All the above mentioned data and result...

Страница 2: ...se of electrical equipment is entirely at your own risk and Motoplat is under no circumstances responsible for any incidental consequential or special damages of any kind whatsoever including but not...

Страница 3: ...on 2 0 Technical specifications 5 2 1 Back panel 6 2 2 Front panel 6 3 Alternator Stator Test 3 0 General information 7 3 1 Common failures 9 3 2 Scan 10 3 3 Test 11 4 Alternator Rectifier Test 4 0 Ge...

Страница 4: ...to identify the phase connections and then checks the windings for any short circuits or connection failures The rectifier test includes checking the circuit connections and measuring their operabilit...

Страница 5: ...nsions MM 219 214 80 Weight KG 3 Stator winding test Voltage V 12 24 Types Star delta Detected failures Inter turn fault Inter phase fault Phases to alternator body Open phase fault Error of measureme...

Страница 6: ...roparly If the fuse need to be replaced turn it counter clock wise to remove it from the tester Plug the supplied test leads into the connection ports of the tester 1 Please note that the number of te...

Страница 7: ...ent equals the rotor frequency multiplied by the number of poles usually 6 Description of an alternator stator winding 1 Winding terminals phases 2 Stator winding 3 Magnetically conductive core Sectio...

Страница 8: ...directly and to reduce area dispersion of the magnetic field The magnetic eld is created in the coils and stator core Several types of stator windings are presented below Windings with a delta connec...

Страница 9: ...f the windings D Incorrect use and storage of an alternator may cause moisture ingress into the unit which may lead to inter turn fault as well Inter phase fault short circuit between phases Inter pha...

Страница 10: ...1 4 and 5 were used In case the stator has 6 outputs star or delta connections commutating to the alternator diode bridge connect 6 cables and press Scan The tester detects the number of connected win...

Страница 11: ...winding inductance The stator is considered to be faultless if the difference between the measured values do not exceed 10 percent Isol Kohm Insulation resistance The value is indicated in kilo ohm Th...

Страница 12: ...rom the center point Rejected Example In the example on the right the connections between phases 2 5 and 5 6 are lost Rejected Example The difference between measured values of windings exceeds 10 Rej...

Страница 13: ...rheating and overcooling Alternator diodes are water proof and protected from all substances 1 alternator diodes 2 positive heat sink 3 negative heat sink Rectifiers can be divided into 2 types I diod...

Страница 14: ...as a large amount of short circuited diodes and diodes with open circuit which will not identify its connections In such cases it is recommended to use additional information on the display amount of...

Страница 15: ...VC 014DS tests the connected rectifier and shows the results on the screen Passed Example The test results of a well functioning three armed rectifier are shown on the right The measuring cables 1 2 3...

Страница 16: ...own on the right The diodes with an open one element circuit are shown in the field open circuit Rejected Short Circuit Example The test results of a rejected three armed rectifier are shown on the ri...