Installation
2-6 Manual # 42-02-2P24
Controller Installation
Mount the controller securely to the machine room floor and use provided wiring knock-outs to
install raceway or conduit to route wires into the cabinet.
Caution
If you drill or cut the cabinet, do not allow metal chips or shavings to fall into electronics.
Damage caused by this is not covered by warranty.
Figure 2.1 Mounting Template for Standard NEMA 1 Cabinet with Feet
27.50
33.50
3.00
7.25
4.25
12.00
2.00
0.75
0.44
Dimensions for attaching base feet of Standard NEMA 1 enclosure (16” deep x 42” wide)
to floor.