![Motion Control Engineering Motion 4000 Скачать руководство пользователя страница 414](http://html1.mh-extra.com/html/motion-control-engineering/motion-4000/motion-4000_manual_1837882414.webp)
Appendix
A-2 Manual # 42-02-2P24
KEB F5 Parameters Table
Enter the settings you make while adjusting into the Field column of the following table.
Table A.1 TorqMax F5 Parameters for Motion 4000
Display
Parameter Description
Unit
Range
Default
Field
WARNING:
Do not change drive parameters while the elevator is running. Incorrect drive
parameter values can cause erratic operation.
WARNING: Parameters with an asterisk (*) must be set correctly for your specific motor /
machine / job. Refer to the adjustment manual for detailed information.
LF. 2
Signal operating mode:
AbSPd - Absolute Analog Speed
d SPd - Digital Speed Selection
A tor - Analog Torque Control
A Spd - Analog Speed Control
SerSP - Serial Com. Speed Control
bnSPd - Binary Speed Selection
S POS – Serial Position feedback
-
AbSPd
d Spd
A tor
A Spd
SerSP
BnSPd
S POS
bnSPd
SerSP
LF. 3
Drive configuration:
run- run mode
conF - Configuration (5 minute time limit)
Stop - Drive stopped, Motor cannot run. Drive
will not respond. When using serial com,
this mode allows parameter changes
S Lrn - activate auto tune
I Lrn - Inertia Learn. Learns the system inertia
and activates the FFTC.
P Lrn: Pole Learn. Learn the pole positions of
PM Motor
SPI - Stationary Pole Learn. Learn absolute
encoder position for PM machine under
brake without sheave movement.
(N/A for software Version 1.61)
OStST - Over speed test function. Allows car to
over speed machine to test governor.
(N/A for software Version 1.61)
-
run
conF
Stop
S Lrn
I Lrn
P Lrn
SPI
OStST
conF
run
LF. 4
Motor-selection: Displays mode selected using US.
4 and US.10
ICLSd - Close loop induction
I9LSS = Closed loop induction gearless
PCLSd = Closed loop permanent magnet (PM)
P9LSS = Closed loop PM gearless
-
see US.10
-
LF. 5
Drive fault auto reset
1
0 - 10
5
LF. 8
Electronic motor overload protection
-
on, off
off
LF. 9
IM - Electronic overload current
PM - not visible, auto set same as LF.12
A
1.0 - 110%
Drive rated
8.0
LF.10
IM - Rated motor power
PM - read only, auto calc.
HP
0.00 - 125.00 5.00
LF.11
Rated motor speed
rpm
10.0 - 6000.0 1165 or
150
LF.12
Rated motor current
A
1.0 - 110%
Drive rated
8.0
LF.13
Rated motor frequency
Hz
4.0 - 100.0
60.0
Содержание Motion 4000
Страница 20: ...xiv Manual 42 02 2P24 5 20 13 ...
Страница 38: ...Motion 4000 Traction Elevator Control 1 18 Manual 42 02 2P24 ...
Страница 178: ...Final Adjustments 3 56 Manual 42 02 2P24 ...
Страница 322: ...User Interface 4 144 Manual 42 02 2P24 ...
Страница 391: ...PC Board Quick References 5 69 5 Motion 4000 Figure 5 11 Example MC CPI Wiring ...
Страница 439: ...Customer Notations A 27 A Motion 4000 Customer Notations Table A 4 Customer Notation Area ...
Страница 444: ...Appendix A 32 Manual 42 02 2P24 ...