Final Adjustments
3-26 Manual # 42-02-2P24
Installation with 2 to 1 Roping
When the EMCO load weigher is used
with 2 to 1 roping, the sensors must be
installed just below the dead-end hitch,
as shown and do not travel with the car.
Therefore, we recommend that in these
cases the EMCO control unit be mounted
in the controller cabinet. The signal wires
from the load cells must be routed
through the overhead to the machine
room. The sensor wires, which are only 6
feet in length, must be extended. Use a
terminal block to join wire lengths and
route wires through conduit.
We recommend enabling the Auto-zero
Calibration option for 2 to 1 roping instal-
lations.
Please refer to “Auto-zero Cali-
To Controller