24
Part Number: 000016427 Rev 00 08/2020
Requirements - Cleaning - Operation
Remedial Cleaning Procedure
This procedure descales all components in the water flow path, and is used between the
bi-yearly detailed descaling and sanitizing procedure.
Ice machine cleaner/descaler is used to remove lime scale and mineral deposits. Ice
machine sanitizer disinfects and removes algae and slime.
NOTE: Although not required and dependent on your installation, removing the ice
machine top cover may allow easier access.
Step 1
Ice must not be on the evaporator during the cycle. Follow one of the methods
below:
• Move the toggle switch to the OFF position at the end of a harvest cycle after ice falls
from the evaporator.
• Move the toggle switch to the OFF position and allow the ice to melt.
,
Caution
Never use anything to force ice from the evaporator. Damage may result.
Step 2
Open the front door and move the toggle switch to the CLEAN or WASH position.
Wait until the water trough refills (approximately 1 minute) and then add the proper
amount of Ice Machine cleaner/descaler to the water trough.
Model
Amount of Cleaner/Descaler
PKU0155
2 ounces (60 ml)
PKM0335/PKM0425/PKM0535
5 ounces (150 ml)
Step 3
After 1 minute place the toggle switch in the ICE position and close and secure
the front door. The ice machine will automatically start ice making after the cycle is
complete (approximately 24 minutes).
Содержание PKM0335
Страница 2: ......
Страница 8: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 64: ...64 Part Number 000016427 Rev 00 08 2020 Troubleshooting THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 98: ...98 Part Number 000016427 Rev 00 08 2020 Troubleshooting THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 130: ...130 Part Number 000016427 Rev 00 08 2020 Specifications THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 131: ......
Страница 132: ...Katom 305 Katom Drive Kodak Tennessee 37764 Part Number 000016427 Rev 00 08 2020 ...