background image

1

F O R M

Installation and Maintenance Instructions for

Models KK, KK-1K - KK-2K, KK-2GD, KK-2GD1K

bore size 15-40 mm Clutch

PS-740-0001

4146-004E

Revised

May 2022

© 2008, 2022 Rexnord Corporation, All Rights Reserved. MCIM22031E • Form# 4146-004E

•  Periodic inspections should be performed. Failure to perform proper 

maintenance can result in premature product failure and personal injury.

•  All electrical work should be performed by qualified personnel and 

compliant with local and national electrical codes.

•  Read and follow all instructions carefully. 
•  Disconnect and lock out power before installation and maintenance. 

Working on or near energized equipment can result in severe injury.

•  Do not operate equipment without guards in place. Exposed 

equipment can result in severe injury or death.

•  Read and understand the information in this section and in this 

manual completely before installing, operating or maintaining this 

equipment. Failure to follow this instruction could result in severe 

injury or death.

GENERAL SAFETY INSTRUCTIONS

indicates a hazard which, if not avoided, will result in 

serious injury or death.

indicates a hazard which, if not avoided, could result in 

minor or moderate personal injury.

indicates a hazard which, if not avoided, could result 

in serious injury or death.

indicates information considered important, but not hazard-

related (e.g. messages relating to property damage).

Motion Control Solutions

Regal Rexnord

111 W. Michigan Street

Milwaukee, WI 53203

Application Engineering: 800 626 2093

regalrexnord.com/Morse

A. Preinstallation

Position clutch so that overrunning direction is compatible to requirements 

of mechanism. Check shaft and bore of housing for correct dimensions 

to insure press fit on both I. D. and O. D. of clutch. (n 6 tolerance on shaft 

and N 6 for housing bore).

Model No.

Recommended 

shaft dia. 

(mm)*, (n6)

Recommended housing dia. (mm)*, 

(N6)

KK15-1K,  

KK15-2GD1K

KK15-2K

KK15-1K/KK15-2K/

KK15-2GD1K

15

-0.008

35

-0.012

35

-0.002

-0.028

-0.028

-0.018

KK17-1K/KK17-2K/

KK17-2GD1K

17

-0.008

40

-0.012

40

-0.002

-0.028

-0.028

-0.018

KK20-1K/KK20 

-2K/KK20-2GD1K

20

-0.010

47

-0.012

47

-0.003

-0.031

-0.028

-0.022

KK25-1K/KK25- 

2K/KK25-2GD1K

25

-0.010

52

-0.014

52

-0.003

-0.031

-0.033

-0.022

KK30-1K/KK30-2K/

KK30-2GD1K

30

-0.010

62

-0.014

62

-0.003

-0.031

-0.033

-0.022

KK35-1K/KK35-2K/

KK35-2GD1K

35

-0.012

72

-0.014

72

-0.006

-0.037

-0.033

-0.025

KK40-1K/KK40-2K/

KK40-2GD1K

40

-0.012

80

-0.014

80

-0.006

-0.037

-0.033

-0.025

*Note: To convert mm to inches, divide by 25.4

Model No.

Recommended shaft  

dia. (mm)*, (n6)

Recommended housing 

dia. (mm)*, (N6)

KK15/KK15-2GD

15

+0.023

35

-0.012

+0.012

-0.028

KK17/KK17-2GD

17

+0.023

40

-0.012

+0.012

-0.028

KK20/KK20-2GD

20

+0.028

47

-0.012

+0.015

-0.028

KK25/KK25-2GD

25

+0.028

52

-0.014

+0.015

-0.033

KK30/KK30-2GD

30

+0.028

62

-0.014

+0.015

-0.033

KK35/KK35-2GD

35

+0.033

72

-0.014

+0.017

-0.033

KK40/KK40-2GD

40

+0.033

80

-0.014

+0.017

-0.033

*Note: To convert mm to inches, divide by 25.4

Отзывы: