√
WFIN-26132/WFOD-26133
WFIN-35132/WFOD-35133
WFIN-50132/WFOD-50133
WFIN-70132/WFOD-70133
Please r
ead this manual c
ar
efully be
for
e use this pr
oduct
Split type Inverter Air Condi oner
USER MANUAL
Страница 1: ...WFIN 26132 WFOD 26133 WFIN 35132 WFOD 35133 WFIN 50132 WFOD 50133 WFIN 70132 WFOD 70133 Please read this manual carefully before use this product Split type Inverter Air Condi oner USER MANUAL...
Страница 2: ...N MANUAL MAINTENANCE TROUBLESHOOTING EMERGENCY FUNCTION AUTO RESTART FUNCTION REMOTE CONTROLLER 2 5 6 7 8 11 18 31 32 I N T R O D U C T I O N T O REFRIGERANTS R32 R290 1 M O D E F A N S L E E P E C O...
Страница 3: ...bove 25 m 2 Above 10 m 2 Above 13 m 2 Above 15 m 2 Above 30 m Warnings Please read the manual before installation using maintenance Do not use means to accelerate the defrosting process or to clean ot...
Страница 4: ...osed of in the separate waste bins Take the air conditioner at the end of its useful life to a special waste collection centre for disposal Only use the air conditioner as instructed in this booklet T...
Страница 5: ...r any other purpose such as for drying clothes cooling food etc The packaging materials are recyclable and should be disposed of in the sparate waste bins Take the air conditioner at the end of its us...
Страница 6: ...not leave windows or doors open for long when the air conditioner is operating Do not direct the airflow onto plants or animals A long direct exposition to the flow of cold air of the conditioner cou...
Страница 7: ...m of the appliance and may not correspond to the appearance of the units that have been purchased No Description 13 Air outlet grille Terminal block cover 14 gas valve 15 liquid valve 16 11 Indoor uni...
Страница 8: ...uring Timer operation when the air conditioner is operational 2 Displays the malfunction code when fault occurs SLEEP mode Lights up during Timer operation SLEEP TIMER 2 3 1 The shape and position of...
Страница 9: ...n 3 sec two beeps will lead to the forced HEATING operation 3 To switch off the unit you just need to press the button again a single long beep 4 After 30 minutes in forced operation the air condition...
Страница 10: ...FAN 5 TIMER ON OFF or To activate or deactivate of the movement of the vertical deflectors PLASMA Mute To activate the function of Mute If applicable To activate the function of Child Lock when press...
Страница 11: ...SIGNAL RECEPTION indicator TIMER OFF indicator TIMER ON indicator AUTO FAN indicator LOW FAN SPEED indicator MIDDLE FAN SPEED indicator HIGH FAN SPEED indicator SLEEP indicator FLAP SWING indicator 15...
Страница 12: ...ects between the remote control and the Signal receptor in the indoor unit 3 Never leave the remote controller exposed to the rays of the sun 4 Keep the remote controller at a distance of at least 1m...
Страница 13: ...n horizontal direction In heating mode orient the flaps downward as the warm air tends to rise The deflectors are positioned manually and placed under the flaps They allow to direct the air flow right...
Страница 14: ...cated MODE FAN SLEEP ECO TIMER SWING MUTE HEALTH DISPLAY SWING I SET TURBO IFEEL CLEAN MODE FAN SLEEP ECO TIMER SWING MUTE HEALTH DISPLAY SWING I SET TURBO IFEEL CLEAN With the button or set a tempera...
Страница 15: ...with the time program the working mode with the button MODE 2 and the fan speed with the button FAN 3 Switch the conditioner off with the key ON OFF Note To cancel the setted function press the TIMER...
Страница 16: ...EL mode automatic the air conditioner auto matically chooses the fan speed and the mode of operation COOLING or HEATING This function reduces the humid ity of the air to make the room more comfortable...
Страница 17: ...y 1 every 60 minutes to achieve a total rise of 2 during the first 2 hours of operation In heating mode the set temperature is gradually decreased by 2 during the first 2 hours of operation After 10 h...
Страница 18: ...s 6 We suggest operate this function per 3 months OPERATING INSTRUCTIONS Self Clean function Indoor unit Outdoor unit Temp 30 5 Temp 30 In each mode of COOLING HEATING FAN DRY adjust the temperature C...
Страница 19: ...ng Heating operating Drying operating 17 C 32 C 0 C 30 C 10 C 32 C 0 C 53 C 15 C 30 C 0 C 50 C The unit does not operate immediately if it is turned on after being turned off or after changing the mod...
Страница 20: ...or bodies and object or objects A leak test must be done after the installation is completed It is a must to do the safety inspection before maintaining or repairing an air conditioner using combusti...
Страница 21: ...flammable limit in kg m h is the installation height of the appliance in meters for calculating m or A 1 8 m for wall max min mounted Table GG 1 Maximum charge kg Category R290 0 038 R32 0 306 LFL 3...
Страница 22: ...pen fire or welding smoking drying oven or any other heat source higher than 548 which easily produces open fire 3 When installing an air conditioner it is necessary to take appropriate anti static me...
Страница 23: ...error must be not more than 5 B The installation site should be equipped with a portable combustible refrigerant concentration detector which can realize two level audible and visual alarm its error m...
Страница 24: ...0 minimum space to be reserved mm showing in the picture 5 0 0 Outdoor unit Indoor unit Outdoor unit Indoor unit Installation Diagram INDOOR UNIT OUTDOOR UNIT The purchaser must ensure that the person...
Страница 25: ...pping screws 5 Be sure that the rear panel has been fixed firmly enough to withstand the weight 1 Make the piping hole 55 in the wall at a slight downward slant to the outdoor side 2 Insert the piping...
Страница 26: ...installation 1 Place the drain hose below the piping taking care not to create siphons 2 The drain hose must slant downwards to aid drainage 3 Do not bend the drain hose or leave it protruding or twis...
Страница 27: ...unit The outdoor unit should be installed on a solid wall and fastened securely The following procedure must be observed before co nnecting the pipes and connecting cables decide which is the best pos...
Страница 28: ...d humidity left inside the refrigerant circuit can cause compressor malfunction After having connected the indoor and outdoor units bleed the air and humidity from the refrigerant circuit by using a v...
Страница 29: ...acuum pump hose 8 Replace and tighten all the caps on the valves 3 way valve diagram connect to indoor unit open position spindle service port cap Connect to outdoor unit Valve core needle INSTALLATIO...
Страница 30: ...rench 15 20 31 35 35 45 75 80 Service port nut Protection caps 7 9 25 30 wrist strength arm strength arm strength arm strength MODEL capacity Btu h 9k 12k 18k 24k Lenght of pipe with standard charge M...
Страница 31: ...l block For different models the wiring diagram may be different Please refer to the wiring diagrams pasted on the indoor unit and outdoor unit respectively On indoor unit the wiring diagram is pasted...
Страница 32: ...to complete installation in case your air conditioner is not including electric cables in its packing 220V air conditioner indoor unit fuse parameter is 50T 3 15A 220V 18K 22K 24K air conditioner outd...
Страница 33: ...ift it till its greatest stroke and then unhooking it from the hinges to make the cleaning easier 2 Clean the indoor unit using a cloth with the water not higher than 40oC and neutral soap Never use a...
Страница 34: ...occurs when the air in the room becomes very cold for example in the COOLING or DEHUMIDIFYING DRY modes This noise is made by the expansion or contraction of the front panel due to variations in tempe...
Страница 35: ...ommunity waste collection recycling centre In the European Union there are separate collection systems for used electrical and electronic products Please help us to conserve the environment we live in...
Страница 36: ...EXCLUSIVE DISTRIBUTOR Amiridis Savidis S A 87A 17th November str 55535 Pylea Thessaloniki Tel 2310 944944 Fax 2316 006650 www morris gr...