Releasing Servo-Controlled Steady Rest Soft-Overtravel
The servo-controlled steady rest stroke is defined in the parameters. If the axis is moved beyond
the stroke limit, the alarm OT0500 or OT0501 occurs and the axis is stopped.
<Release procedure>
1)
Place the DOOR INTERLOCK key-switch in the
NORMAL
position.
2)
Close the front door.
3)
Place the PANEL key-switch in either of the positions indicated below.
(ON)
(PANEL/EDIT)
4)
Select the manual mode.
5)
Move the axis in opposite direction to the overtravel direction using handle feed, jog feed, or
rapid traverse operation.
6)
Press the
(RESET) key.