B-18 MANUAL OPERATION
6-1
Zero Return Operation
In manual operation, each axis is returned to the machine zero point at the set rapid traverse rate.
The machine zero point varies depending on the machine model and specifications.
For details, refer to the DRAWINGS.
Zero return operation must be carried out in the following cases:
1.
After the power is turned on
2.
Before setting the tool offset data for newly mounted tools
3.
After the machine ready signal has been turned off due to the EMERGENCY STOP button
being pressed, etc.
4.
After changing the machine lock function setting from "valid" to "invalid"
1)
Place the DOOR INTERLOCK key-switch in the
NORMAL
position.
2)
Close the front door.
3)
Place the PANEL key-switch in one of the positions
indicated below.
(ON)
(PANEL/EDIT)
4)
Press the head selection switch
(head 1) or
(head 2) to select the required turret.
WARNING
Never stand near the moving parts of the machine during a zero return
operation since each axis is returned to the zero point at the rapid
traverse rate.
Before starting a zero return operation, always make sure that no one is
standing near the moving parts and that the moving parts can be fed to the
zero point without interference.
Failure to observe these warnings could result in accidents involving
serious injuries or damage to the machine: operators or personnel near
the machine could be crushed by the moving parts of the machine, and
the turret could strike obstacles.
DOOR INTERLOCK
NORMAL
RELEASE
ON
PANEL
/EDIT
OFF
PANEL
1
2