A-18 OPERATION PANELS
5-3
Panel Key-Switch [PANEL]
The PANEL key-switch is used to select the operation
range of the switches on the machine operation panel and
to enable or disable editing of a program.
After turning on the power supply, first check the setting of
this key-switch.
Setting the PANEL key-switch to the appropriate position
(
(OFF),
(ON)) protects the stored programs from
being changed carelessly and also prevents operation
error caused by erroneous switch operation during
automatic operation.
Switch
Position
Machine Operation,
Program Editing
Function
Operation: Disabled
Edit: Disabled
When this position is selected, operation of the switches on
the machine operation panel is impossible.
Therefore, programs stored in memory cannot be edited.
Select this position so that the switches on the machine
operation panel will not be used carelessly during automatic
operation.
The key can be removed when the PANEL key-switch is
placed in this position.
When this position is selected, the following
switches remain valid:
EMERGENCY STOP button, CYCLE switches,
OVERRIDE dial, tailstock switches, LIGHT switch,
chip conveyor switches and coolant switches.
Operation: Enabled
Edit: Disabled
When this position is selected, operation of the switches on
the machine operation panel is possible.
However, programs stored in memory cannot be edited.
The key can be removed when the PANEL key-switch is
placed in this position.
Operation: Enabled
Edit: Enabled
When this position is selected, operation of the switches on
the machine operation panel is possible.
In addition, programs stored in memory can be edited.
The key cannot be removed when the PANEL key-switch is
placed in this position.
ON
PANEL
/EDIT
OFF
PANEL
OFF
NOTE
ON
PANEL
/EDIT