101
Rev. 1.1
2018/04
400-820-9661
M2DC Series Hardware Manual
7.4.3 Basic Settings For Analog Torque Mode
7.4.3.1 Command Signal For Analog Torque Mode
In Analog input torque mode, both single ended and differential signal are acceptable.
Single Ended Analog Input
Pin Type
Signal Name
Connector pin
allocation
Function
Input
ANA2
18
Analog torque input signal
DGND
17
Analog torque input signal grounding
Single ended analog input
18
ANA2
17
DGND
+
-
±10VDC
Differential Analog Input
Pin Type
Signal Name
Connector pin
Function
Input
ANA1
16
Analog torque input for differential input signal
ANA2
18
DGND
15
Analog torque input signal grounding
Differential analog input
16
15
+
-
18
17
+
-
Host controller
D/A Output
DGND
DGND