Moons' Applied Motion Products TXM24-S/Q Скачать руководство пользователя страница 1

TXM

TXM24-S/Q Quick Setup Guide 

Requirements

To begin, make sure you have the following equipment:
• 

A small flat blade screwdriver for tightening the connectors (included).

• 

A 12-70V DC power supply.

• 

A personal computer running Microsoft Windows 98, 2000, ME, NT, XP, Vista or 7 (32 or 64 bit) and Windows 8.

• 

Step-Servo Quick Tuner software (available at www.applied-motion.com/products/software).

• 

A 3004-277-5M power cable, 3004-290-5M I/O cable (optional), and for RS-232 models: 3004-278-5M RS-232 

programming cable.

•  NOTE: The 3004-278-5M Programming Cable is NOT included and must be purchased separately.

For RS-485 models: an RS-422 or RS-485 port or adapter for your PC (see reverse for recommended RS-485 

adapter)

• 

For more detailed information, please download and read the TXM24 Hardware Manual, available at www.applied-

motion.com/support/manuals.

Step1

Step2

a)

 Download and install the Step-Servo Quick Tuner software.

b) 

Launch the software by clicking: Start / Programs / Applied Motion Products / Step-Servo Quick Tuner

c) 

Select the correct COM port using the drop down list

d) 

Connect the drive to your PC using the RS-232 programming cable or RS-422/485 adaptor 

Wire the drive to the DC power source.

(Do not apply power until Step 3)

Note - the TXM24 accepts DC voltages from 12-70V. If using an external 

fuse, we recommend a 5 amp fast acting fuse.

(See the TXM24 Hardware Manual for more information about power 

supply and fuse selection.)

Connect I/O, if required by your application. A 3004-290-5M cable will be 

required.

(See the TXM24 Hardware Manual for more information about wiring I/O 

to the TXM24.)

GND

EMI Filter

  AC

Power

 Input

LINE

LOAD

L

N

N

L

V+

V-

P/N:092.00823.00 (LCR)

4

3

1

2

POWER

DC POWER

  SUPPLY

V-

V+

V+

V-

GND

920-0092 Rev C