Applied Motion Products, Inc.
Hardware Manual
STRAC8
AC Input Step Motor Drive
920-0128 Rev C
03/26/21
Страница 1: ...Applied Motion Products Inc Hardware Manual STRAC8 AC Input Step Motor Drive 920 0128 Rev C 03 26 21...
Страница 2: ...Switch Selection 12 4 1 Microstep Resolution 12 4 2 Running Current 13 4 3 Idle Current 13 4 4 Anti Resonance 14 4 5 Step Input Mode 14 4 6 Step Input Signal Filter 14 4 7 Step Smoothing Filter 14 4 8...
Страница 3: ...000 steps rev Running Current peak setting switch selectable 16 settings 0 4 0 6 0 9 1 2 1 5 2 0 2 5 3 0 3 5 4 0 4 5 5 2 5 9 6 6 7 3 8 0A Idle Current automatic reduction of running current 1 second a...
Страница 4: ...15V reg 3 3V reg LED Power Supply STRAC8 Block Diagram 2 Mounting the Drive The STRAC8 drive can be mounted only on the narrow side of the chassis M4 screws should be used in the two holes at the back...
Страница 5: ...are Manual 920 0128 Rev C 03 26 21 3 Connections To use the STRAC8 Step Drive the following items are needed Universal AC input of 90 to 240 VAC Pulse Direction signal A compatible step motor STRAC8 W...
Страница 6: ...ting fuse Earth Ground green Neutral white Line hot black Regeneration Clamping Circuit High speed motion generates high voltage which can be transferred to the drive during rapid deceleration and the...
Страница 7: ...elded cables See the Recommended Motors section for a list of part numbers The recommended motors should be connected to 120V drives in parallel and to 220V drives in series according to the diagram b...
Страница 8: ...6 lead motor Grn Wht White Green Red Red Wht Black 6 Leads Series Connected 6 Leads Center Tap Connected Eight lead motors can also be connected in two ways series and parallel As with six lead motor...
Страница 9: ...IR They accept 5 to 24 volt single ended or differential signals up to 2MHz The maximum voltage that can be applied to the input is 28V The motor executes one step when the STEP input closes The direc...
Страница 10: ...maximum voltage that can be applied to the input is 28V When EN input is closed the driver amplifier is deactivated all the MOSFETs will shut down and the motor will be free When EN input is open the...
Страница 11: ...ically isolated The maximum collector current is 100mA and the maximum collector to emitter voltage is 30 volts The output can be wired to sink or source current When drive is working normally the out...
Страница 12: ...Smoothing Filter 4 1 Microstep Resolution The microstep resolution is set by the SW1 SW2 SW3 and SW4 switches There are 16 settings Microstep steps rev SW1 SW2 SW3 SW4 200 ON ON ON ON 400 OFF ON ON O...
Страница 13: ...N OFF OFF 7 3A ON OFF OFF OFF 8 0A OFF OFF OFF OFF SW5 SW6 SW7 SW8 5 6 7 8 5 6 7 8 5 6 7 8 5 6 7 8 5 6 7 8 5 6 7 8 5 6 7 8 5 6 7 8 5 6 7 8 5 6 7 8 5 6 7 8 5 6 7 8 5 6 7 8 5 6 7 8 5 6 7 8 5 6 7 8 5 6 7...
Страница 14: ...ection format the ON position enables the CW CCW format Note The power must be cycled each time the position of SW13 is changed 4 6 Step Input Signal Filter The STEP and DIR signal inputs have a built...
Страница 15: ...NOTE When the motor selection is changed the drive power supply will need to be cycled SW position MOTOR WIRING Input Voltage Input Voltage 0 Reserved Reserved 0 A 1 Reserved Reserved 0 A 2 HT23 552...
Страница 16: ...z in sec 2 Motor Length inch mm Connection Drive Current Setting amps phase Connection Drive Current Setting amps phase HT34 495 695 parallel 5 10 series 2 55 555 2 27E 02 3 11 79 HT34 496 696 paralle...
Страница 17: ...0 20 30 40 50 60 HT34 495 oz in HT34 696 oz in HT34 697 oz in 0 200 400 600 800 1000 1200 1400 1600 0 10 20 30 40 50 60 HT34 495 oz in HT34 696 oz in HT34 697 oz in HT23 552 553 554 220V Step Resolu o...
Страница 18: ...sabled If the red LED flashes an error has occurred Errors are indicated by combinations of red and green flashes as shown below Code Error Solid green Motor Disabled Flashing green Motor Enabled 3 re...
Страница 19: ...8000 10000 20000 25000 ON ON ON ON ON OFF ON ON ON ON ON ON ON OFF OFF OFF ON ON ON OFF ON ON ON ON ON OFF OFF OFF OFF OFF OFF OFF ON ON ON OFF ON ON ON ON ON OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF O...
Страница 20: ...l Voltage 4 0 28 V OUT Maximum Output Current 100 mA OUT Maximum Output 30 V 7 2 2 Environmental Specifications Environmental Specifications Heat Sinking Method Natural cooling or fan forced cooling S...
Страница 21: ...21 STRAC8 Hardware Manual 920 0128 Rev C 03 26 21 8 Contacting Applied Motion Products 404 Westridge Dr Watsonville CA 95076 USA 1 800 525 1609 www applied motion com...