0747-SOM-00002-02
Page 28 of 33
Updating the Genesis software version on the SSC
The Tethered system is supplied with a content management cable assembly. When plugged into the
sonar port on the SSC this cable enables an Ethernet connection to be setup between the SSC and
the users PC or laptop. By installing and using the ‘Content Management Tool’, a separate software
utility, the user can then install any future updates of the Genesis sonar control GUI loaded onto the
SSC.
Before using the cable you must install the Content
Management Tool application onto your Windows PC.
This program is available from the USB pen drive
supplied with your DMD system.
After installation a purple DMD SSC Management icon will be placed
onto your desktop.
The IP address of the DMD SSC is set to 192.168.2.60 and default address of the
Gemini sonar 192.168.2.201. To communicate with the SSC over the Content
Management Cable you must have your Ethernet network adapter
manually
set to
a corresponding IP address 192.168.2.xxx (example 192.168.2.101) with Subnet
Mask 255.255.255.0.
Do not set the PC network address to the same as the DMD SSC or Gemini
sonar.