P
ar
t
2: C
omman
d
s
Moog Animatics SmartMotor™ Developer's Guide, Rev. L
Page 791 of 909
VTS=formula
Velocity Target, Synchronized Move
APPLICATION:
Motion control
DESCRIPTION:
Sets the synchronized (path) velocity target
EXECUTION:
Must be set before issuing PTS or PRTS; will not be effective
after that point
CONDITIONAL TO:
PID
n
LIMITATIONS:
Must not be negative; 0 is not valid
READ/REPORT:
None
WRITE:
Write only
LANGUAGE ACCESS:
Assignment
UNITS:
(encoder counts / sample) * 65536 in 2D or 3D space
RANGE OF VALUES:
0 to 2147483647
TYPICAL VALUES:
100000 to 3200000
DEFAULT VALUE:
0
FIRMWARE VERSION:
5.x series only; not available in version 5.32.x.x
COMBITRONIC:
N/A
DETAILED DESCRIPTION:
NOTE:
This command requires a Combitronic-supported motor. Although this
command does not support Combitronic syntax, it does use Combitronic
communication to pass information between other motors.
The VTS command sets the maximum velocity target for synchronized moves. The motion
along a synchronized move is defined along the path in 2D or 3D space depending on the
number of axes defined by PTS or PRTS.
The VTS command is specific to defining the
combined
velocity of all contributing axes. For
example, if the move were to occur in an X-Y plane, the velocity set by VTS would not pertain
to the just the X- or Y-axis. Rather, it applies to their
combined
motion in the direction of
motion.
The value of VTS defaults to zero. Therefore, it must be given a value before any motion can
take place.
A useful Scale Factor Multiplier code example, which also illustrates the use of af[], SAMP and
RES, is shown in RES on page 670 and SAMP on page 690.