P
ar
t
2: C
omman
d
s
Moog Animatics SmartMotor™ Developer's Guide, Rev. L
Page 400 of 909
ECHO_OFF
Turn Off Echo on Communications Port 0
APPLICATION:
Communications control
DESCRIPTION:
Disable motor echo of received channel 0 serial data
EXECUTION:
Immediate; remains in effect until otherwise commanded
CONDITIONAL TO:
N/A
LIMITATIONS:
N/A
READ/REPORT:
N/A
WRITE:
N/A
LANGUAGE ACCESS:
N/A
UNITS:
N/A
RANGE OF VALUES:
N/A
TYPICAL VALUES:
N/A
DEFAULT VALUE:
Motor defaults to ECHO_OFF (non-echo)
FIRMWARE VERSION:
5.x and later
COMBITRONIC:
N/A
DETAILED DESCRIPTION:
The ECHO_OFF command causes the SmartMotor™ channel 0 COM port to stop echoing. This
is the default power-up state of any SmartMotor. No incoming channel 0 characters are
retransmitted.
In order to automatically detect and differentiate between multiple motors on a serial daisy-
chain cable, the ECHO state can be alternately turned on and off to ensure the motors are
properly addressed.
NOTE:
It is not possible to maintain communications on a serial chain without
issuing ECHO.
EXAMPLE:
ECHO_OFF
'Remove echo from channel 0
EIGN
(
W
,0)
'
Make all onboard I/O inputs
ZS
'Clear errors
RELATED COMMANDS:
Echo Incoming Data on Communications Port 0 (see page 396)
Echo Incoming Data on Communications Port 1 (see page 399)
Turn Off Echo on Communications Port 1 (see page 402)
Part 2: Commands: ECHO_OFF
Содержание SmartMotor
Страница 1: ...Developer s Guide Class 5 Later SmartMotor Technology with TM ...
Страница 909: ...PN SC80100003 002 Rev L ...