Position Controller Implicit I/O Messages
This section describes the details about implicit I/O messages for the device.
General Command and Response Message Types
This section describes the formats for consumed and produced general messages.
l
The standard CIP Position Controller I/O connection messages are 8-byte messages.
l
The Class 6 EtherNet/IP SmartMotor supports both the standard 8-byte format and an
extended 32-byte format.
l
The first eight bytes of the 32-byte format match the 8-byte format defined in the ODVA
CIP Position Controller specification. The SmartMotor will select which message format
to use based on the host controller connection size.
Connection
Size
Description
8 bytes
The motor will use the CIP standard communication format and Command Mes-
sage Types
32 bytes
The motor will use:
l
CIP Standard 8 byte messages
l
Additional Data Fields in the Command / Response Message frames
l
Extended Command Message Types 6 (Position Move) & 7 (Velocity
Move)
Any other
The motor will respond with an error
The default connection size used in the Class 6 EtherNet/IP SmartMotor EDS file is 32-bytes.
NOTE:
Implicit I/O messages are the most efficient method of exchanging cyclic
data, such as Target Position and Actual Position, with the SmartMotor. These mes-
sage types for the Position Controller Polled I/O Connection are typically the best
choice for commanding the SmartMotor shaft position or applied torque.
Содержание SmartMotor SM34165MT-IP
Страница 16: ......
Страница 24: ......
Страница 30: ......
Страница 36: ......
Страница 98: ......
Страница 126: ......
Страница 153: ...SmartMotor AOI Example Moog Animatics Class 6 EtherNet IP Guide Rev B Page 153 of 160...
Страница 154: ......
Страница 158: ......
Страница 159: ......
Страница 160: ...PN SC80100010 001 Rev B...