17.2.2 Loading the parameter data set from the
file system
No.
Action
1
Load the parameter set from the PC to the file system of the servo
drive via FTP script:
open 192.168.39.5
Servo
Drive
mkdir /para
cd /para
put PDS
00
.dmd
quit
The parameter data set is now present in the servo drive file system.
2
Enter the name of the parameter data set to be read
With byte 0 of
P 2010[0] - COM_CFG_ID
: Specifies the name of the data
set to be read.
0-99
means PDS
00
...PDS
99
.
3
Specify options:
With byte 1 of
P 2010[0] - COM_CFG_ID
:
Specification of the options.
Bit 0 = 1: Save the data set permanently to the non-volatile servo drive.
4
Read the parameter data from the file system and write to the device
parameters.
P 2009[0] - COM_CFG_File
= 19.
5
If everything has worked properly,
P 2009[0] - COM_CFG_File
is
automatically set to 0 = Ready once again.
If there is an error,
P 2009[0] - COM_CFG_File
is set to -2 = error.
MOOG
ID No.: CB40859-001 Date: 11/2020
MSD Servo Drive - Device Help
460
17 Enhanced/additional functions