17.1.2 Parameter list
ID
Index
Name/Setting
Unit Description
97
PARA_
DataSetLdCfg
DataSet Loader Configuration
0
Opt
Configuration options
OFF (0)
Function not active
ON(1)
Activate function
1
FS:
Function selector
0 = OFF
No data set ID is determined.
1 = TERM
Determination via digital inputs (MPRO_INPUT_STATE
& PARA_DataSetLdCfg[1])
2 = PARA
The data set ID is determined from a selectable
parameter. The value of the parameter (Para_
ID/ParaSubID) is used to generate the data set ID.
2
Mask
Bitmask
3
ActID
Currently selected data set ID
4
Para_ID
Parameter index for generating the data set ID (if
FS=PARA)
5
Para_SubID
Parameter subindex for generating the data set ID (if
FS=PARA)
6
Para_Scale
The parameter value is scaled (multiplication) for the
generation of the data set ID using the value indicated.
7
Para_Offset
Parameter offset for generating the data set ID
98
PARA_
DataSetLdID
0 -99
PARA_
DataSetLdID
List of the possible data set IDs
99
PARA_
DataSetLdVal
0 -99
PARA_
DataSetLdVal
Associated character strings which describe
parameters and values which are to be changed
Table 16.5: Parameter “Reloading individual parameters”
Activation
The function is activated by the setting of the parameter P 97 - PARA_DataSetLdCfg
[0] Opt = 1.
Determining the data set ID
MOOG
ID No.: CB40859-001 Date: 11/2020
MSD Servo Drive - Device Help
456
17 Enhanced/additional functions
The parameter P 97 - PARA_DataSetLdCfg[1] FS is the function selector and
specifies which source is used for determining the data set ID.
The parameter P 97 - PARA_DataSetLdCfg[2] (= PARA_DataSetLd_Mask) functions
in this case as the bitmask for selecting (e.g. the desired digital inputs).
off (0)
Manual switchover via ActID
1
Switchover via digital inputs
2
Switchover via separate parameter
The currently determined data set ID is displayed in parameter P 97 - PARA_
DataSetLdCfg[3] (= ActID).
Manual allocation of the data set ID
If parameter P 97 - PARA_DataSetLd_FS = OFF(0), then the data set ID can be
allocated “manually.”
Every imaginable data set ID should be entered in parameter P 98 - PARA_
DataSetLdID[x] at least once under any subindex desired.
Automatic data set ID determination
Parameter P 97 = Para(2) allows switching between the data set IDs via any
parameter desired (for example, a fieldbus parameter). To do so, the parameter must
be entered in P 97.4 and the associated subindex in P 97.5. The value of the
parameter entered is overwritten in P 97.3.
Using parameter P 97 - PARA_DataSetLd_FS = PARA(2), the data set ID is
determined automatically from the current value of the parameter specified by P 97 -
PARA_DataSetLdCfg[4] and P 97 - PARA_DataSetLdCfg[5] and is entered in P 97
- PARA_DataSetLd [3] = ActId.