11.6.42.4 Error 45-3 (emergency code 8612h)
Cause: Software limit switch overtravel detected, traversing task rejected
Suggested steps:
Quit error and change reference value
The reference value violates
a lock or limit switch.
l
Please check reference values. If this axis is
working in cyclic synchronous mode, make a
scope record.
l
Check factor group settings.
l
Check mode of operation.
This issue is probably
caused by an unsuitable
parameter setting.
l
Save your parameter set for a later restore.
l
See 'history of parameter changes' and undo
the latest changes.
l
Please check your parameter set for
implausible settings.
l
Please set device to factory setting, restart, and
see if the error occurs again.
l
When reporting this error to your service
partner, please include your device's
parameter setting.
MOOG
ID No.: CB40859-001 Date: 11/2020
MSD Servo Drive - Device Help
423
11 Alarms & warnings
11.6.43 Error 46: Position limit error
11.6.43.1 Error 46-0 (emergency code 8612h)
Cause: Unknown position limit error
Suggested steps:
Switch off/on device. Please contact your service provider if this error occurs again
Position was limited
internally.
l
Please check factor group setting and position
command
l
Take a scope record to determine if the
position control overshoots.
The speed control might run
away, most likely due to a
wrong encoder offset.
l
Please check that the encoder offset is set
properly.
l
If auto commutation is used, re-view the auto
commutation setting and test under all
possible conditions.
l
If torque mode is used, reduce torque, ensure
external speed limitation, or increase speed
control gain for stronger limitation.