11.6.28 Error 28: Encoder channel 3, cyclic process error
11.6.28.1 Error 28-1 (emergency code 7307h)
Cause: Channel 3 cyclic, Np (distance coded): error, measured 'counter distance' is
out of range
Suggested steps:
Please check the wiring of the encoder
Encoder channel, cyclic
evaluation
l
Error during the cyclic evaluation of an
encoder channel 3.
l
In any case look at init outputs in the message
window of the
Moog D
RIVE
A
DMINISTRATOR
5 .
l
The most common cause of error is the wiring
to the encoder.
MOOG
ID No.: CB40859-001 Date: 11/2020
MSD Servo Drive - Device Help
399
11 Alarms & warnings
11.6.28.2 Error 28-2 (emergency code 7307h)
Cause: Channel 3 cyclic, Np (distance coded): error, delta correction failed
Suggested steps:
Please check the wiring of the encoder, perhaps reduce the speed.
Encoder channel, cyclic
evaluation
l
Error during the cyclic evaluation of an
encoder channel 3.
l
In any case look at init outputs in the message
window of the
Moog D
RIVE
A
DMINISTRATOR
5 .
l
The most common cause of error is the wiring
to the encoder.
11.6.28.3 Error 28-3 (emergency code 7307h)
Cause: Channel 3 cyclic, Np (distance coded): error, calculated 'delta' is out of range
Suggested steps:
Please check the wiring of the encoder
Encoder channel, cyclic
evaluation
l
Error during the cyclic evaluation of an
encoder channel 3.
l
In any case look at init outputs in the message
window of the
Moog D
RIVE
A
DMINISTRATOR
5 .
l
The most common cause of error is the wiring
to the encoder.