MSD Servo Drive AC-AC Operation Manual
moog
50
Id. no.: CA65642-001 Date: 03/2012
4.4.4 Ethernet IP-address menu (IP)
An Ethernet TCP/IP interface serves the purpose of service and diagnostics interface.
The IP-address is factory set to 192.168.39.5. It can be changed with the PC software
Moog
D
rive
A
DministrAtor
5 or via the display.
Menu level
Pa-
ram-
eter
Value
range
Meaning
Explanation
1
2
IP
Iu
b0
00..FF
IP address
udate Byte 0
Setting of byte 0 of the IP-address in
hexadecimal representation
(e.g. “05” at 192.168.39.
5
)
b1
00..FF
IP address
udate Byte 1
Setting of byte 1 of the IP-address in
hexadecimal representation
(e.g. “27” at 192.168.
39
.5)
b2
00..FF
IP address
udate Byte 2
Setting of byte 2 of the IP-address in
hexadecimal representation
(e.g. “A8” at 192.
168
.39.5)
b3
00..FF
IP address
udate Byte 3
Setting of byte 3 of the IP-address in
hexadecimal representation
(e.g. “C0” at
192
.168.39.5)
Ir
-
-
IP reset to
factory setting
To reset the IP-address to factory setting
(192.168.39.5)
Su
b0
00..FF
Subnetmask
udate Byte 0
Setting of byte 0 of the subnet mask in
hexadecimal representation
(e. g. “00“ at 255.255.255.
0
)
b1
00..FF
Subnetmask
udate Byte 1
Setting of byte 1 of the subnet mask in
hexadecimal representation
(e. g. “FF“ at 255.255.
255
.0)
b2
00..FF
Subnetmask
udate Byte 2
Setting of byte 2 of the subnet mask in
hexadecimal representation
(e. g. “FF“ at 255.
255
.255.0)
b3
00..FF
Subnetmask
udate Byte 3
Setting of byte 3 of the subnet mask in
hexadecimal representation
(e. g. “FF“ at
255
.255.255.0)
Sr
-
-
Subnetmask
reset to
factory setting
To reset the subnet mask to factory
setting (255.255.255.0)
Table 4.8 IP-address menu
Exemplary configuration of the subnet mask
In this example the subnet mask is changed from 255.255.255.0 auf 122.255.255.0.
T1
T2
Tx
Tx
Back
Back
Back
Apply
>5 s
>5 s
<5 s
T2
<5 s
T1 T2
T1 T2
T1 T2
Back
T1 T2
Back
T1 T2
T1 T2
T1 T2
T1 T2
T1
T2
T1
T1
Back
T1 T2
T2
Press button Tx
(x=1, 2) repeatedly
until desired menu
appears on display
Press button Tx
(x=1, 2) once
Press any button
Press button T1 and T2
simultaneously
Value NOT
saved
Value
saved
Fig. 4.2 Exemplary configuration of the subnet mask
Содержание G392-004
Страница 1: ...moog MSD Servo Drive AC AC Operation Manual Single Axis System AC AC 4 A to 450 A...
Страница 83: ......