G395-084 to G395-210, liquid cooling
Designation
Technical data
G395-084
G395-110
G395-143
G395-170
G395-210
Output, motor side
1)
Voltage
6)
3-phase U
Mains
Rated current, effective (l
N
)
84 A
110 A
143 A
170 A
210 A
Peak current
See A.1.5
Rotating field frequency
0 ... 400 Hz
Switching frequency of the power stage
4, 8, 12, 16 kHz
Input, mains side
Mains voltage
(3 x 230 V/ 3 x 400 V/ 3 x 460 V/ 3 x 480 V) ±10 %
Device connected load
(with mains choke)
52.6 kVA
2)
76 kVA
99 kVA
118 kVA
128 kVA
3)
Current
1)
(with mains choke)
76 A
2)
110 A
143 A
170 A
185 A
3)
Asymmetry of mains voltage
±3 % maximum
Frequency
50/60 Hz ±10 %
Power dissipation at I
N
1)
1130 W
1500 W
1940 W
2380 W
2650 W
1)
Data referred to mains voltage 3 x 400 V
eff
and switching frequency of the power stage 8 kHz
2)
The input current must be limited to 76 A
3)
The input current must be limited to 185 A
4)
Connection of an ext. braking resistor to devices with int. braking resistor not permitted (model G395-xxx-xxx-xx2)!
5)
Cooling performance adequate also with optional internal braking resistor
6)
When designing the drive, it is to be taken into account that the maximum output voltage reduces as a function of the active power.
Table A.13 Technical data, G395-084 to G395-210, liquid cooling
Designation
Technical data
G395-084
G395-110
G395-143
G395-170
G395-210
DC link
Capacitance
900 µF
2120 µF
4240 µF
Brake chopper switch-on threshold
820 V DC
Minimum ohmic resistance of an
externally installed braking resistor
4)
10
Ω
12
Ω
10
Ω
8.5
Ω
6.5
Ω
Brake chopper peak power with external
braking resistor
67 kW
56 kW
67 kW
79 kW
103 kW
Option: internal braking resistor
10 Ω
7.5 Ω
5 Ω
Brake chopper continuous power with
internal braking resistor
1350 W
2650 W
4000 W
Brake chopper peak power with internal
braking resistor
67 kW
90 kW
135 kW
Chiller data
Coolant pressure
(rated value / maximum value)
1 / 2 bar
Coolant flow rate
5)
(rated value / maximum value)
8 / 11 l
per min
11 / 13 l per min
Feed coolant temperature
The coolant temperature can be b5 °C (+41 °F) and +40 °C
(+104 °F). However, the coolant temperature should not be more than
10 °K below the ambient temperature to prevent condensation on the heat
sink.
1)
Data referred to mains voltage 3 x 400 V
eff
and switching frequency of the power stage 8 kHz
2)
The input current must be limited to 76 A
3)
The input current must be limited to 185 A
4)
Connection of an ext. braking resistor to devices with int. braking resistor not permitted (model G395-xxx-xxx-xx2)!
5)
Cooling performance adequate also with optional internal braking resistor
6)
When designing the drive, it is to be taken into account that the maximum output voltage reduces as a function of the active power.
Table A.13 Technical data, G395-084 to G395-210, liquid cooling
Содержание G305-170
Страница 1: ...moog AC AC Servo Drive Single axis System 4 A to 450 A MSD Servo Drive Operation Manual...
Страница 6: ...6 MSD Single Axis System Operation Manual AC AC Servo Drive ID no CA65642 001 06 2018 moog...
Страница 60: ...60 Diagnostics MSD Single Axis System Operation Manual AC AC Servo Drive ID no CA65642 001 06 2018 moog...
Страница 82: ...82 MSD Single Axis System Operation Manual AC AC Servo Drive ID no CA65642 001 06 2018 moog...
Страница 88: ...88 MSD Single Axis System Operation Manual AC AC Servo Drive ID no CA65642 001 06 2018 moog...
Страница 89: ...89 MSD Single Axis System Operation Manual AC AC Servo Drive ID no CA65642 001 06 2018 moog...