![Moog ACV Series Скачать руководство пользователя страница 312](http://html1.mh-extra.com/html/moog/acv-series/acv-series_user-manual_1831452312.webp)
Moog ACV with CANopen bus interface
8 Diagnostics
Troubleshooting
B99224-DV018-D-211, Rev. A, October 2018
285
8.4.1.23 0x32: Software coding
8.4.1.24 0x33: Software reset (watchdog) occurred
8.4.1.25 0x34: Interrupt time exceeded
Error Code:
0x32
Error Name:
Software coding
Description:
An internal software error (deadlock, illegal code operation) caused an restart of the
valve
Severity of error:
Major
Action:
Send valve back to factory for service.
Error Code:
0x33
Error Name:
Software reset (watchdog) occurred
Description:
-
Severity of error:
Major
Action:
-
Error Code:
0x34
Error Name:
Interrupt time exceeded
Description:
The internal interrupt task time has exceeded. The number of tasks and the time to
calculate them exceeds the time limitation of the so-called interrupt. Not all interrupt
tasks were calculated.
Severity of error:
Major
Action:
• Check the task time
• Reduce the number of tasks
• Reduce interface usage
• Change control mode
If the error occurs often or on a daily basis, even after reevaluation of all tasks, send
the valve back to factory for service.
Do not store your application in state 'HOLD' or 'ACTIVE'.