7.2.8.1 Object 0x6342: Type
This parameter is used to select the compensation type or to switch off the dead band compensation function.
Value description
7.2.8.2 Object 0x6343: A side
This parameter defines the step height of the dead band on the positive side.
Chapter "2.4.3 Units and prefix parameter", page 12
7.2.8.3 Object 0x6344: B side
This parameter defines the step height of the dead band on the negative side.
Chapter "2.4.3 Units and prefix parameter", page 12
ValvePositionControl_DemandValueGenerator
Index
Sub-index
Parameter name
Data type
Access
Per-
sistence
Value range
Default
0x6342
0
DeadbandCompensation_Type
INT8
rw
Y
0…2
0
<DeadbandCompensation_Type>
Description
0
Dead band compensation switched off.
1
Dead band jump function.
2
Dead band continuous function (recommended).
Table 77: Possible values of parameter <DeadbandCompensation_Type> (0x6342)
ValvePositionControl_DemandValueGenerator
Index
Sub-index
Parameter name
Data type
Access
Per-
sistence
Value range
Default
0x6343
1
DeadbandCompensation_ASide
INT16
rw
Y
0…16384
0
0x6343
2
Unit
UINT8
ro
-
UINT8
0
0x6343
3
Prefix
INT8
ro
-
INT8
0
ValvePositionControl_DemandValueGenerator
Index
Sub-index
Parameter name
Data type
Access
Per-
sistence
Value range
Default
0x6344
1
DeadbandCompensation_BSide
INT16
rw
Y
0…16384
0
0x6344
2
Unit
UINT8
ro
-
UINT8
0
0x6344
3
Prefix
INT8
ro
-
INT8
0