1. INTRODUCTION

This manual provides instructions and procedures necessary

to install, operate and troubleshoot the Moog Inc. Series 79-100 Industrial

Servovalve. Loop closure of the third stage spool requires external electronics –

consult factory for suggested Moog electronics model numbers.

2. OPERATION

The Moog Inc. Series 79-100 Industrial Servovalve consists of a two stage

mechanical feedback pilot valve and a high flow third stage with electrical

feedback. Proper operation requires the use of user provided electronics to

condition the spool position transducer, compare actual spool position to

command and to generate a current signal to the pilot valve.

In a typical system, a spool position command signal is compared to the

actual spool position signal in the servoamplifier.The error (difference) is

converted to a current signal and used to drive the pilot valve spool in the

proper direction.The pilot valve spool directs oil flow to one end of the third

stage spool, moving the spool. Spool movement is sensed by the spool position

transducer and spool motion continues until the spool position signal is equal

to the command signal.At this point, the servoamplifier current returns to near

zero, the pilot valve returns to null and the third stage spool is held in position.

79-100 Series Installation and

Operation Instruction

Electrohydraulic Servovalve

CAUTION

DISASSEMBLY, MAINTENANCE, OR REPAIR OTHER THAN IN ACCORDANCE WITH THE

INSTRUCTIONS HEREIN OR OTHER SPECIFIC WRITTEN DIRECTIONS FROM MOOG WILL

INVALIDATE MOOG’S OBLIGATIONS UNDER ITS WARRANTY.