SPECIFICATION NUMBER:

81-IN5392

MODEL:

EOC1N

High-Speed Ethernet over Coax
STANDARD INSTALLATION PROCEDURE

 

EOC1N units are used to convert conventional Ethernet to 
a signal that can be carried by 75ohm coaxial video cables 
such as RG59.

 

EOC1N makes it possible to upgrade installed analogue 
cameras to high-quality digital IP cameras without the 
expense of replacing existing cabling.

  In the example shown a pair of EOC1N units is used to allow 

an IP (network) camera to communicate with other network 
devices over an existing coaxial video cable.

GENERAL INSTRUCTIONS

1.  Mounting

  

 

!

The EOC1N unit should only be installed indoors or  

 

in an appropriately rated enclosure.

 

If the unit is to be located on a horizontal surface then the 
enclosed rubber feet should be affixed to the underside of 
the enclosure. The unit should be securely mounted and 
should not be supported by the attached cables. 
Mounting bracket part no VHW -WMB can be used for 
bolting the unit to a wall or structure. Rack panel part no 
VHW-1U allows installation of up to eight EOC1N units in 1U 
of a 19 inch rack. The unit’s chassis should be earthed using 
either a mounting bracket or a ground strap, secured by the 
BNC connector nut, before any other cables are connected 
Inline ground isolator part no VHW-XF should be fitted where 
there is a significant ground potential difference between 
each end of the cable.

2. Power Connection

 

EOC1N should only be used with a Class II Isolated power 
supply. The unit can be powered from either a 12V DC 
or 24V AC power supply (PSU), and adjusts to its type 
and voltage automatically. If the PSU is shared with other 
equipment such as a camera, ensure that the total load 
current will not exceed the PSU’s rated output. If in any 
doubt, measure the voltage at the PSU’s connector before 
and after connecting the EOC1N or other equipment, to 
ensure it is within range. If an existing power supply is not 
available, up to two EOC1N units can be powered by PSU 
part no VWH-12VPSU-xx (xx = UK or USA). Part no VHW-
RMPSU-xx is designed for rackmount installations and can 
power up to eight units. The PSU cables should be bared, 
tinned and securely connected to the EOC1N power plug 
before switching on the PSU. Only one wire should be 
connected to each of the power plug’s screw terminals, 
with polarity as indicated on the unit’s top panel. The green 
LED will blink every 1~2 seconds to indicate the presence of 
power.

3. Coaxial Cable Connection

 

Connect the unit’s BNC socket to the coaxial cable. If 
another EOC1N unit is connected at the far end and 
powered up, then the green LED will light steadily to indicate 
a good connection. In some installations, cable condition 
will force the units to reduce their connection speed, and 
this is indicated by the green LED flashing (approximately 
half-on, half-off). Only two units should be connected, one 
at each end of the cable. EOC1N is not compatible with 
other equipment such as analog video amplifiers.

4. Ethernet Cable Connection

 

Connect the unit's RJ45 Ethernet jack to the camera or 
other network equipment using a standard Ethernet cable. 
Both patch and crossover type Cat5 or Cat6 cables are 
supported. The amber LED will light to indicate a network 
connection, and will blink off during network activity.

Manufacturer’s Declaration of Conformity

The manufacturer declares that the equipment enclosed with
this certificate conforms with the essential protection
requirements of the EMC Directive 89/336/EEC and has
been designed and manufactured to the following
specifications:
BS EN 55022:1998 Emissions (Radiated)
BS EN 55024:1998 Immunity
BS EN 61000-4-2:1995 Immunity to ESD
BS EN 61000-4-3:20002 Immunity to Radiated RF Fields
(3V/m).

PRODUCT INSTRUCTIONS

REVISION DATE:

 

March 12, 2007

CO-AXIAL VIDEO CABLE

NVR

NETWORk CABLE

NETWORk CABLE

EOC1N

EOC1N

Power 

cable

Network 

cable

Coaxial 

video 

cable