Diagnosis and LED signals
The IBU-NG provides the following LED signals to display the described statuses:
LED
Color Status
Meaning
SENS
green continually on
blinking
Connection with
PulseNG
sensor OK
No connection with
PulseNG
sensor
Possible causes:
Not plugged in correctly or broken cable
STAT
green continually on
continually off
Device ready
Device not ready
IN1-IN5
yellow continually on
Shows respective input status, depending on
whether contact is designated as normally
open (N.O.) or normally closed (N.C.).
OUT1-
OUT5
red
continually on
Shows respective output status, depending
on whether designated normally open (N.O.)
or normally closed (N.C.) contact.
Only OUT1 red
continually on
Device in boot loader mode
* Current IP address: 192�168�1�241
Table 4: Diagnosis and LED signals
Sensor Connection
A 4 pin M8 round connector with pins connects
PulseNG
sensor and IBU-NG.
PulseNG
Dimensions
Figure 4:
PulseNG
Height
Width
Depth
30 mm
40 mm
11 mm
Table 5:
PulseNG
sensor dimensions