background image

 17 12 " 

 14 12 " 

 8" 

 5" 

 11" 

 9 14 " 

External Power Vent Head -  PVHEX58-300

     An all new design for the 

Montigo line of Power Vent 

heads that re-defines how an 

external power vent can 

perform without compromizing 

the aesthetics of your building. 

These new power heads use the 

best fan technologies for years 

of reliable service. The 

PVHEX58-300 design minimizes 

the visual impact by using a 

side intake / bottom exit design 

to eliminate the previous 

louvered / slotted look. As well, 

the 300cfm capicity is large 

enough to handle high btu 

residental fireplaces and uses 

standard 5" x 8" co-axle 

venting. Brushed Stainless 

Steel construction assures 

corrosion free life and a modern 

attractive look. 

IF YOU SMELL GAS

  Do not try to light any appliance.

  Do not touch any electrical switch;  do not use any phone in your building.

  Immediately  call  your  gas  supplier  from  a  neighbor's  phone.  Follow  the  gas 

supplier's instructions.

  If you cannot reach your gas supplier, call the fire department.

DANGER

Irritant

Cutting

Watch your step

Slippery floor

High temperatures

Glass hazard

Danger of suffocation

High voltage 

Toxic 

Flammable materials

Corrosive

Fork lift trucks 

Danger overhead crane

Explosion risk

Oxidising

Danger of death 

Biohazard

Laser Radiation

Danger of entrapment

Hot surface

General Warning

Blank

Gas bottles

Watch for 

falling objects

Electricity

Danger for cutter

Entrapment hazard

Battery hazard

Rotating parts

Low temperature

Strong magnetic field

Optical radiation

Non ionizing

 radiation

Radiation

Hazardous to the

Environment

Danger of harming 

your hands

Irritant

Cutting

Watch your step

Slippery floor

High temperatures

Glass hazard

Danger of suffocation

High voltage 

Toxic 

Flammable materials

Corrosive

Fork lift trucks 

Danger overhead crane

Explosion risk

Oxidising

Danger of death 

Biohazard

Laser Radiation

Danger of entrapment

Hot surface

General Warning

Blank

Gas bottles

Watch for 

falling objects

Electricity

Danger for cutter

Entrapment hazard

Battery hazard

Rotating parts

Low temperature

Strong magnetic field

Optical radiation

Non ionizing

 radiation

Radiation

Hazardous to the

Environment

Danger of harming 

your hands

Irritant

Cutting

Watch your step

Slippery floor

High temperatures

Glass hazard

Danger of suffocation

High voltage 

Toxic 

Flammable materials

Corrosive

Fork lift trucks 

Danger overhead crane

Explosion risk

Oxidising

Danger of death 

Biohazard

Laser Radiation

Danger of entrapment

Hot surface

General Warning

Blank

Gas bottles

Watch for 

falling objects

Electricity

Danger for cutter

Entrapment hazard

Battery hazard

Rotating parts

Low temperature

Strong magnetic field

Optical radiation

Non ionizing

 radiation

Radiation

Hazardous to the

Environment

Danger of harming 

your hands

Irritant

Cutting

Watch your step

Slippery floor

High temperatures

Glass hazard

Danger of suffocation

High voltage 

Toxic 

Flammable materials

Corrosive

Fork lift trucks 

Danger overhead crane

Explosion risk

Oxidising

Danger of death 

Biohazard

Laser Radiation

Danger of entrapment

Hot surface

General Warning

Blank

Gas bottles

Watch for 

falling objects

Electricity

Danger for cutter

Entrapment hazard

Battery hazard

Rotating parts

XG0517

031114

 

PVHEX58-300 

 

Installation & Maintenance Manual

Installer:

 Leave this manual with the appliance. 

Consumer:

 Retain this manual for future reference. 

NOTICE

 

 

Glass doors on gas fireplaces are 

extremely hot

 while the fireplace is on and 

remain hot even after the fireplace has been turned off. 

CAUTIO N

This fireplace is 

equipped with a safety screen. Do not operate the fireplace without the safety 

screen. Keep children away from the fireplace at all times.  

If the information in these instructions is not followed exactly, a fire or explosion

may result causing property damage, personal injury or death. 

WARNING

Glass doors on gas fireplaces are 

extremely hot

 while the fireplace is on and 

remain hot even after the fireplace has been turned off.  Safety screens are 

available and can reduce the risks of severe burns.  Please keep children away 

from the fireplace at all times.

CAUTION

This fireplace is certified to ANSI Z21.50 / CSA 2.22 Vented Fireplace Standard as a

power assisted direct vent fireplace. This product uses outdoor air for combustion and

and exhausts combustion products outdoors.   

NOTICE

 

Canadian Heating Products Inc. 

Langley, BC  V4W 4A1   |   

Montigo Del Ray Corp.

 Ferndale, WA  98248

This power vent is approved for use with Montigo RP-Series fireplaces. 

NOTICE

Содержание PVHEX58-300

Страница 1: ...er of harming your hands Irritant Cutting Watch your step Slippery floor High temperatures Glass hazard Danger of suffocation High voltage Toxic Flammable materials Corrosive Fork lift trucks Danger overhead crane Explosion risk Oxidising Danger of death Biohazard Laser Radiation Danger of entrapment Hot surface General Warning Blank Gas bottles Watch for falling objects Electricity Danger for cut...

Страница 2: ...PVHEX58 300 Vertical Power Vent System Safety Alert Key 3 Introduction 3 Product Dimensions 4 Installation 5 Wiring Diagram 6 7 Appendix 8 9 Appendix A Warranty 8 Appendix B State of Massachusetts 9 Page 2 XG0517 031114 ...

Страница 3: ... 20 foot power cord and harness EPVH30 30 foot power cord and harness EPVH40 40 foot power cord and harness EPVH50 50 foot power cord and harness EPVH60 60 foot power cord and harness EPVH70 70 foot power cord and harness EPVH80 80 foot power cord and harness EPVH90 90 foot power cord and harness EPVH100 100 foot power cord and harness Specifications Before Your Begin Voltage 115 Volts Frequency 6...

Страница 4: ... 8 203 18 1 4 465 22 1 4 566 17 1 4 439 21 1 4 541 2 51 13 330 4 1 2 114 19 7 8 505 9 1 2 241 6 1 8 156 15 7 8 403 13 330 5 127 8 203 Top View 22 1 4 566 2 51 13 330 4 1 2 114 19 7 8 505 9 1 2 241 6 1 8 156 5 127 8 203 PVHEX58 300 External Horizontal Power Vent Rear View 18 1 4 465 22 1 4 566 17 1 4 439 21 1 4 541 19 7 8 505 9 1 2 241 6 1 8 156 15 7 8 403 13 330 13 330 Power Head Framing Kit Vent ...

Страница 5: ...e through the Rough in kit as shown using the strain relief where the wire enters the Rough in kit Figure 2b Securing the Power Vent Rough in Kit Step 3 1 Attach the power cord comming from the Power Head to the receptical in the Rough in box 2 Place the Power Head into the Rough in kit and attach with 4 screws provided 3 Finishing material can be applied to the exterior wall Step 3 Attach the pow...

Страница 6: ...earances are maintained for the wiring and conduit When installing the wiring it must never run above the vent run and it must be at least 1 clear of all venting 1 Clearance Wire Figure 3 Conduit and Wiring Wiring Installation 2 Place the Power Head into the Rough in kit and attach with 4 screws provided 3 Finishing material can be applied to the exterior wall Figure 2d Securing the Power Vent Rou...

Страница 7: ...White Black Blk Wht Wht Blk Blue Red Brown NC Heat Sensor NO Flue Gas Switch ELECTRICAL CONTROL BOX R3 Gas Valve Wall Switch Fuse 115 Volts 60Hz 5A Post Purge Timer Pre Purge Timer Honeywell Q3450 Pilot Assembly Pilot Electrical Harness Connector Honeywell Gas Control SV9501M Gas Control Connector Green Black White Switch or Dimmer Not Supplied Power for Lights 115VAC 700W FIREPLACE CONTROLS Red T...

Страница 8: ... Appliance must be subjected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability It is expressly agreed and understood that The Companies sole obligation and purchaser s exclusi...

Страница 9: ...rade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upo...

Страница 10: ...Ferndale Washington TF 1 800 789 6236 FX 1 866 3000 0927 XG0517 031114 Langley British Columbia TF 1 800 378 3115 FX 1 604 607 6462 PVHEX58 300 Power Vent Termination ...

Отзывы: