Appendix

XG0799 - 081319

Prodigy series fireplaces are standard with 2 intake dampers and are 

available with optional exhaust dampers that prevent airflow through 

the fireplace’s ducting when the unit is turned off. Dampers are typically 

used in cold climates to prevent condensation buildup on the inside 

of fireplace glass or vent pipes due to the mixing of warm inside and 

cold outside air. When installed with a Prodigy fireplace, dampers are 

electrically integrated into the Montigo control panel so that no additional 

start-up steps are required. The system with or without dampers is 

controlled by a single wall switch. The figures below illustrate typical 

damper options.

Damper Wiring

Dampers require additional electrical wiring between the control panel 

and the damper. A five conductor cable is supplied for this connection, 

and the wire functions are as follows:

•  White and Black: 24 VAC supply to damper motor
•  Red and Brown: End switch
•  Green: Ground

  9.88 

  9.75 

 5.00 

 11.00 

 5.00 

 21.00 

OUTLET

INLET

 18.06 

 9.84 REF. 

  13.07 

 

*NOTE: PART NUMBER USED

TO BE '

DAMPER10IN

' FOR ALL

CONFIGURATIONS.

THIS CHANGED ON 05FEB15

 

CONFIGURATION PART NUMBERING:

 

DAMPER10   -

NO COLLARS

DAMPER10CS -

SINGLE COLLAR

DAMPER10EX -

EXTERNAL PV COLLAR

DAMPER10IN -

INLINE (2 COLLARS)

 

!IMPORTANT!

 

For Flue Gas

applications,

maintain at least

2.00" clearance

to combustibles

all around the

Damper

 

MODEL No.

DAMPER10IN

INLET COLLAR

ø9.88"

OUTLET COLLAR

ø9.75"

WEIGHT (lbs)

POWER OUTPUT 

TO DAMPER

24VAC, 5VA

1:8

SIZE DWG.  NO.

A

REV.

SHEET 1 OF 1

WEIGHT:

DAMPER10IN

FINISH

MATERIAL

DIMENSIONS ARE IN INCHES

TOLERANCES:

FRACTIONAL    1/32"

TWO PLACE DECIMAL      .015"

THREE PLACE DECIMAL    .005"

ALL BENDS ARE ASSUMED

TO BE 90  UNLESS NOTED 

OTHERWISE.

CHECKED BY

DRAWN BY

DATE

NAME

25/08/2016

10" MODULAR DAMPER, 

INLINE (2 COLLARS)

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CANADIAN HEATING PRODUCTS IS PROHIBITED.

PROPRIETARY AND CONFIDENTIAL

August-25-16 3:09:27 PM

SCALE

Damper System Overview

Power vent

Power 

vent wire

Flue gas 

damper wire

Combustion 

air damper 

wires

Power supply 

wire 208W, 

15B

Control 

Panel

Control 

cable 9 

wire

LED Power 

120V, 2A

Wall 

switch

B Vent 

Appendix C: Dampers

Содержание Prodigy PC3 Series

Страница 1: ...partment Installation and service must be performed by a qualified installer service agency or the gas fitter PRODIGY SERIES INDOOR GAS FIREPLACE SINGLE SIDED SEE THROUGH CORNER RIGHT LEFT PANORAMA FRAMELESS LINEAR FIREPLACE Natural Gas or Propane Gas Read and understand this manual Improper installation adjustment alteration service or maintenance can cause serious injury property damage or even ...

Страница 2: ... installation operation and maintenance manual is applicable to the models described in Figure 1 Refer to your rating plate to verify included options Warranty and Installation Information See Appendix B The Montigo warranty will be voided by and Montigo disclaims any responsibility for the following actions Modification of the fireplace and or components including power vent module or glass doors...

Страница 3: ... Around the Fireplace 16 Television Installation 16 Mantle and Hearth 16 Prodigy Indoor Outdoor Kit Dimensions 17 Prodigy Indoor Outdoor Kit 18 Section 5 Wiring 19 Control Panel Installation 19 Electrical Connection Directions 21 Damper Connections 21 Section 6 Installing the gas line 22 Section 7 Start Up 23 LED Remote Control Operation 24 LED Troubleshooting 24 Pairing the Remote to the Module C...

Страница 4: ...uired to safely and efficiently run this unit has been pre determined and must not be altered without consultation with the factory A heat sensor switch will turn off the burner if a restricted fresh air intake causes vent temperatures to rise Some locations allow for fresh air to be drawn from the room in which the fireplace is installed This type of installation is acceptable from a functional p...

Страница 5: ...12 PRODIGY SPECIFICATIONS PC3 PC4 PC5 PC6 PC7 PC8 MAXIMUM INPUT NATURAL GAS BTU HR 40 000 50 000 75 000 88 000 100 000 112 000 MAX INPUT PROPANE BTU HR 31 000 52 000 64 000 78 000 105 000 120 000 REQUIRED B VENT 8 10 10 10 10 12 SIZE OF INTAKES 2 x 6 2 x 8 2 x 8 2 x 8 2 x 8 2 x 10 TOTAL EQUIVALENT FREE AREA OF INTAKE 56 52 sq inches 100 48 sq inches 100 48 sq inches 100 48 sq inches 100 48 sq inch...

Страница 6: ...1 83 95 E 12 20 30 36 60 F 8 G 42 54 66 78 90 102 H 15 I 23 Glass Height J 26 3 16 Glass Height K 19 PANORAMA DIMENSIONS 3 4 5 6 7 8 AIR INTAKE 2 x 6 2 x 8 2 x 10 EXHAUST 8 10 12 A 4315 16 5515 16 6715 16 7915 16 9115 16 10315 16 B 24 32 40 48 56 60 C 13 3 8 D 43 55 67 79 91 103 E 12 20 30 36 60 F 8 G 47 59 7115 16 8315 16 9515 16 10715 16 H 15 I 23 Glass Height J 26 3 16 Glass Height K 19 A A B B...

Страница 7: ... I J D E C F Dimensions shown for corner right unit dimensions are the same for corner left configuration Gas and electrical connections will always be opposite the corner side NOTICE There are framing brackets built into the face of the Prodigy fireplace These brackets extend 1 outwards from the body and are recessed 5 8 to allow for installation of cement board around the fireplace See specific ...

Страница 8: ...uirementspleasecontact your local Montigo representative Install components and fittings using the clearances specified by the B Vent manufacturer All joints must be secured as per the instructions provided by the B Vent manufacturer Horizontal runs must be supported by a minimum of three supports per 10 feet of venting Select a location for the power vent that will permit an access panel for futu...

Страница 9: ... 120V 2A Wall switch A B B Vent B or C Vent B or C Vent MODEL SIZE 3 4 5 6 7 8 A 7 7 8 9 7 8 9 7 8 9 7 8 9 7 8 11 7 8 B 10 5 16 12 5 16 12 5 16 12 5 16 12 5 16 14 5 16 Power supply wire 208V 15A 153 16 61 16 191 8 3215 16 231 2 MAX Maintain at least 1 clearance around the collar sheild 305 16 305 16 1213 16 24 2 1 ...

Страница 10: ...le 9 wire LED Power 120V 2A B Vent A B MODEL SIZE 3 4 5 6 7 8 A 7 7 8 9 7 8 9 7 8 9 7 8 9 7 8 11 7 8 B 10 5 16 12 5 16 12 5 16 12 5 16 12 5 16 14 5 16 Power supply wire 208V 15A B or C Vent B or C Vent 61 16 5 213 16 321 2 305 16 305 16 109 32 21 2 1 Maintain at least 1 clearance around the collar shield 241 4 241 4 ...

Страница 11: ... Additionally the Power Vent must be securely mounted in a manner which also allows the possibility for the access door to be opened The Motor Access Door must have at least 12 of additional clearance to be able to pull out the Motor Access Door Fan Wheel assembly for servicing The structure which the Power Vent is mounted to must be Non Combustible Material Only CAUTION B or C Vent B or C Vent 85...

Страница 12: ...IAL C VAULT _CUSTOM VENTILATION SYSTEMS BOXES VB Vent _Spec Dwgs FLUE GAS FGLVBI 10 Tuesday May 28 2019 11 12 53 AM SCALE 21 700 24 820 19 746 22 856 C C 22 880 21 800 20 746 1 1 2 6 380 3 892 9 7 8 19 800 SECTION C C IMPORTANT Maintain at least 1 00 clearance to combustibles all around the Flue Gas Box This flue gas box is only to be used with Montigo fireplace systems specifically approved by Mo...

Страница 13: ...HE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CANADIAN HEATING PRODUCTS IS PROHIBITED PROPRIETARY AND CONFIDENTIAL December 05 17 9 16 10 AM SCALE CALVB COMBUSTION AIR VENT BOX w LOUVER 8 CALVB 08 13 75 OPENING FOR LOUVER 15 70 OPENING FOR LOUVER 18 820 16 856 A A 14 75 1 50 5 40 1...

Страница 14: ... once the unit has been placed in its final location STEP 1 Frame around the fireplace as desired Framing can be installed on all sides of the fireplace or only on the top and sides if a thinner finishing material will be used Ensure access is left for connections of gas electrical and venting as required STEP 2 Complete all venting gas and electrical connections STEP 3 Backframe the unit with fra...

Страница 15: ...AMING DIMENSIONS 3 4 5 6 7 8 B 42 54 66 78 90 102 C 26 3 16 Glass Height CORNER AND PANORAMA FRAMING DIMENSIONS 3 4 5 6 7 8 B 42 54 66 78 90 102 C 26 3 16 Glass Height Recessing the Back Edge For corner and panorama configurations Be sure to measure to confirm facing material will still clear the side glass 19 18 19 19 B B B B C C C C ...

Страница 16: ...is designed for zero clearance installation That is combustible finishing materials may be installed directly against the fireplacebody Thesematerialscanbefasteneddirectlytothefireplace provided the fasteners do not penetrate further than 1 2 into the unit or impede glass installation To ensure glass can be safely removed for cleaning it is recommended that flush finishing materials not extend mor...

Страница 17: ... Kit Dimensions INDOOR OUTDOOR KIT DIMENSIONS 3 4 5 6 7 8 A 37 49 61 73 85 973 16 B 40 52 64 76 88 100 C 40 52 64 76 88 100 D 37 49 60 7215 16 85 97 E Glass Height 1 F 109 16 G 8 H Glass Height 13 16 I 4 Glass Height J 12 Glass Height A B G H I J D E C F ...

Страница 18: ...required Step 6 Finishing Around Fireplace When installing finishing materials around the fireplace leave a gap between the stainless trim and any finishing materials so that the trim can be removed for cleaning and servicing Step 2 Frame The window kit is designed to extend through an outer wall constructed of 2 x6 framing Frame around the fireplace throat using 2 x6 material and keeping the fram...

Страница 19: ...er 5A 125V 2 EC1456 Circuit breaker 15A 250V 2 EC1142 TransformerClass2 Input110VAC60Hz Output24VAC40VA 7 EC1214 Socket Relay 5 EC1213 Relay w indicator light 24VAC 2 EC1215 Relay w indicator light 110VAC 1 EC1413 Fixed DOM Timer 60 Sec 1 EC1035 Control Timer Delay 120VAC 10 AMPS 1 EC1203 Terminal Block 10 Pole 1 EC2050 Inverter 200 240V 4kW 1 GC3073 Direct Ignition Module 1 GC3097 Rectifier Cable...

Страница 20: ...llation XG0799 081319 Power Vent Inverter Power Vent Reversal Switch Pre Purge Timer Post Purge Timer Relays w LED 6 Transformers Connections Damper Connection Fuse Panel Control Panel opened Control Panel side ...

Страница 21: ...blacks L1 and L2 white neutral and green ground Connection Step 4 Connect 120V power to the base of the fireplace to power the LED lighting inside the unit This is a two wire connection consisting of a black hot and white neutral wire Damper Connections The prodigy comes standard with 2 intake dampers a flue gas damper is available for order separately Follow the below instructions on the damper w...

Страница 22: ...which has been under water Note After gas line is connected each appliance connection valve and valvetrainmustbecheckedwhileundernormaloperatingpressurewith either a liquid solution or leak detection device to locate any source of leakage Tighten any areas where bubbling appears or leak is detected until bubbling stops completely or leak is no longer detected DO NOT use a flame of any kind to test...

Страница 23: ...nverter will ramp from 0 to the last used speed but in the reverse direction indicated by a negative sign 10 The flue gas relay is activated within 10 to 15 seconds of the power vent running at an adequate speed If the flue gas relay is not activated after 30 seconds increase the speed of the power vent 11 The ignition system relay will power up after the pre purge time 60 seconds 12 The ignition ...

Страница 24: ...le 20 Circulation mode Item Parameters Working Voltage AAA 2pcs 3V Radio Frequency 2400 2483 5MHz Modulate Method GFSK Transmit Power 6db Standby Power Consumption 10uA Remote Distance 20 30m Dimension 110 52 30mm Figure 30 LED remote Figure 30 b Remote parameters Figure 30 c Remote modes Montigo s series fireplaces have integrated LED lighting installed beneath the burner tray The LEDs are contro...

Страница 25: ...um of 4 remotes NOTE If remote fails to pair with controller remove batteries from remote and let it sit for 2 minutes this way all residual power will be drained Install batteries back and repeat pairing procedure For Version 2 0 LED Remote Indicating light on color wheel is opaque 3 Within 3 seconds after power supply indicator goes on press S button 4 To clear a remote s pairing follow the same...

Страница 26: ...ttheunit scombustionairsupplyhasnotbeenblockedorrestricted If the Heat Sensor Relay turns OFF the cause is overheating Increase the power vent s speed to increase cooling and the fireplace will automatically restart once the unit s temperature reaches a safe level If the inverter display shows either a current limit alarm H001 or an overload alarm H002 it could mean that the unit s output is set t...

Страница 27: ...g pressure on the glass in the top track Section 8 Installing Removing the Glass 3 Slide the glass downward carefully until it is free from the upper clips Store in a safe location until time to replace 4 At each end of the unit between the inner glass and outer glass there is a channel held in place by 2 screws Remove these screws and the channel and store them in a safe place for re installation...

Страница 28: ...l result in fireplace sooting Section 9 Installing the Accessories Optional speckled stones Burner Media Quantities Do not cover the pilot with any media Figure 22 Do not cover the pilot with any media Speckled stones 50pc RR50SS Speckled stones 150pc RR150SS Speckled stones 300pc RR300SS Speckled stones 600pc RR600SS Driftwood logset Large LGS57 Driftwood logset Medium LGS58 Driftwood logset Smal...

Страница 29: ... vent purge 3 min Flue gas relay on 1 minute system purge Contact Montigo Tech Support YES YES Less than 200VAC YES YES YES YES YES NO NO NO NO NO NO NO NO Turn wall switch on Measure L1 to L2 Power vent not connected Increase power vent speed Reverse power vent direction Flue gas relay on Pressure switch trip Failed purge timer Power vent off Flame not in contact with spark Poor burner ground Con...

Страница 30: ...ol system and any gas control which has been under water Cleaning When the fireplace is first activated there may be some smoke and a visible film may be left on the glass This is a normal condition and is the result of burning of protective coatings on new metal Glass must be cleaned periodically to remove any film which is a normal by product of combustion which may be visible Film can easily be...

Страница 31: ...sive temperatures will result in a fire hazard and void all warranties This warranty is transferable The appliance must remain in its original place of installation to be valid If the components of the appliance covered by this warranty are found to be defective within the time frame stated see The Companies investigation of claims The Companies will at its option replace or repair defective compo...

Страница 32: ...ot responsible for work done without written consent of The Companies The Companies shall in no event be responsible for any warranty work done without first obtaining the Companies written consent The Companies employees and dealers have no authority to make any warranties to neither alter this warranty nor authorize any remedies in addition to or inconsistent with those stated within this warran...

Страница 33: ...Clearance to forced air supply inlet 6 feet 3 feet above inlet N Clearance between Montigo combustion and exhaust terminations for combustion termination beside or below exhaust vent 30 inches 30 inches for combustion termination above exhaust vent 3 feet 3 feet P Clearance above paved sidewalk or paved driveway located on public property 7 feet 7 feet Q Clearance under veranda porch deck or balco...

Страница 34: ... above forced air supply inlet or Montigo combustion air termination 3 feet 3 feet M Clearance to sides or bottom of Montigo combustion air termination 6 inches 6 inches N Clearance above paved sidewalk or paved driveway located on public property 7 feet 7 feet P Clearance under veranda porch deck or balcony 12 inches 12 inches Q Clearance above roof 2 feet 2 feet R Clearance to adjacent walls and...

Страница 35: ... 00 0 OUTLET INLET 18 06 9 84 REF 13 07 NOTE PART NUMBER USED TO BE DAMPER10IN FOR ALL CONFIGURATIONS THIS CHANGED ON 05FEB15 CONFIGURATION PART NUMBERING DAMPER10 NO COLLARS DAMPER10CS SINGLE COLLAR DAMPER10EX EXTERNAL PV COLLAR DAMPER10IN INLINE 2 COLLARS IMPORTANT For Flue Gas applications maintain at least 2 00 clearance to combustibles all around the Damper MODEL No DAMPER1 INLET COLLAR ø9 88...

Страница 36: ...XG0799 081319 Installation Maintenance Manual PRODIGY SERIES 3 TO 8 Single Sided See Through Corner Panorama ...

Отзывы: