Operation
SIT Proflame 2 Electronic Ignition
To Turn Off Gas To Appliance:
1.
Turn off fireplace using wall switch or remote control.
2. Remove the lower Horizontal access panel.
3. Turn the incoming gas control valve to "Off".
4. Replace the lower Horizontal access panel.
with American Flame Electronic Ignition
For Your Safety - READ BEFORE LIGHTING:
Lighting Instructions:
phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the Fire De-
partment.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by hand,
don't try to repair it, call a qualified service technician. Force
or attempt to repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system, and
any gas control which has been under water.
A. This appliance is equipped with an ignition system that lights
the pilot burner automatically. Do not attempt to light the pilot
by hand.
B. BEFORE LIGHTING smell all around the appliance area for
gas. Be sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.
What To Do If You Smell Gas:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone
in your building.
Immediately call your gas supplier from a neighbour's
1. STOP! Read the safety information above on this label.
2. Remove the lower Horizontal access panel.
3. Turn "ON" manual "ON/OFF" switch located below the hori-
zontal access panel (if available).
4. Turn Incoming gas valve to the ON" position.
5. Wait 5 minutes to clear out any gas. If you smell gas, STOP!
Follow "B" in the safety information above on this label. If
you don't smell gas, go to the next step.
6. Turn fireplace "ON" using wall switch or remote control.
7. If the Fireplace does not light, the System will cycle through
two trials, (one minute audible clicking, thirty seconds of
silence, and then another one minute of audible clicking).
If the system locks out due to inadequate gas flow, refer to
"Troubleshooting" in instruction guide.
8. After completion of the information in the Troubleshooting
section, Repeat step 5.
9. If the system will not function correctly, follow the instruc-
tions "To Turn Off Gas To Appliance" and call your service
technician or gas supplier.
If the information in these instructions is not followed exactly, a fire or explosion may
result causing property damage, personal injury or death.
WARNING
WARNING/ CAUTION: Hot while in operation. Do not touch.
Severe burns may result. Keep children, clothing, furniture,
gasoline and other liquids having flammable vapours away.
See installation and operating instructions accompanying this
appliance.
Typical Control Module shown
Gas Valve
Manifold Pressur
e
Test Connection
Pilot Adjustment Screw
Hi Lo Adjustment
Inlet Pressur
e
Test Connection
SW1
LED1
LED2
SW1 = Programing Button
LED1 = Red Diagnostic Light
LED2 = Amber Programing Remote Control Light
Power
3.15A Fuse
Stepper Motor
Main Harness
Main ON/OFF Switch
Sensor
Igniter
Operation