34
Installation
XG0199 - 170223
Do not place any materials or objects on top of the valve blind. Doing
so could result in failure of door relief system or heat dissipation.
When covering the upper metal portion of the fireplace with a non-
combustible material. Please note the decorative facing materials may
be subject to temperatures in excess of 250°F. This should be considered
when selecting facing materials.
WARNING
IMPORTANT
Mantels & Surrounds
NOTE: National Canadian Gas Association mantel test requirements
are for fire hazard prevention to combustible materials.
New technology, to meet consumer and government demands for the
wise use of energy, has prompted us to manufacture many models of
fireplaces which are hot, fuel and energy efficient.
Please be aware, temperatures over the mantel will rise above normal
room temperature and walls above fireplace may be hot to touch.
NOTE:
UNIT CANNOT BE RECESSED INTO A WALL
Side wall clearances are 3". Combustible surrounds may be installed
with 3" clearance to the side of the fireplace as shown in Figure 21.d
Figure 21.d
Combustible surrounds.
(image shown without screen for clarity)
4”Non-Combustible
Facing Material
Non-combustible Header
Drywall/Sheetrock
4”
3”
4”Non-Combustible
Facing Material
Drywall/Sheetrock
Non-combustible Header