M40DV-CR/CL Corner Gas Fireplace

Appendix A - Termination Locations

A

 =  clearance to the termination frame above grade, veranda, porch, deck, 

or balcony [16 inches (41 cm) minimum] 

B

 =  clearance to door, or sides and top of window, that may be opened [16 

inches (41 cm) minimum for appliances 

100 000 BTU/H (30kW)] 

C

 =  clearance to bottom of  window that may be opened horizontally [36 

inches (92 cm) minimum for appliances 

100 000 BTU/H (30kW)] 

D

 =  no clearance to permanently closed window when installed with ap

-

proved glass penetration termination

E

 =  clearance to permanently closed  window [16 inches 41 cm recom

-

mended to prevent condensation on window]

F

 =  vertical clearance to ventilated soffit located above the termination 

within a horizontal distance of 2 feet (61 cm) from the centreline of the 

termination [22 inches (56 cm) minimum]

G

 =  clearance to unventilated soffit 

 

[16inches (41 cm) minimum to non-combustibles]  

 

[22 inches (56 cm) minimum to combustibles]

H

 =  clearance to outside corner [9 inches (23 cm) minimum]

I

 =  clearance to inside corner [12 inches (31 cm) minimum]

J

 =  * not to be installed above a meter/regulator assembly within 

 

40" (103 cm) horizontally from the centreline of the regulator

K

 =  clearance to service regulator vent outlet [3 feet  minimum in the United 

States] [*6 feet  (1.8 m) minimum in Canada]

=  clearance to nonmechanical air supply inlet to building or the combus

-

tion air inlet to any other appliance [16 inches (41 cm) minimum for 

appliances 

100 000 BTU/H (30kW)]

M

 =  clearance to mechanical air supply inlet 

 

[*6 feet  (1.8 m) minimum]

N

 = 

 clearance above paved sidewalk or a paved driveway located on 

public property [*7 feet (2.1 m) minimum]

P

 =  clearance under veranda, porch, deck, or balcony 

 

[16 inches (41 cm) minimum

 to non-combustibles]

 

[22 inches (56 cm) minimum

 to combustibles]

Q

 =  clearance above a roof [24 inches (61 cm) minimum]

R

 =  clearance to adjacent walls and neighbouring buildings 

 

[18 inches (46 cm) minimum]

S

 =  clearance from corner in recessed location 

 

[12 inches (31 cm) minimum]

T

 =  maximum depth in recessed location

 

 [48 inches (122 cm) minimum]

U

 =  minimum width for back wall of recessed location

 

 [24 inches (61 cm) minimum]

V

 =  no horizontal clearance between the frames of two terminations that 

are level.

W

 =  horizontal clearance between the frames of two terminations that are 

not level.  [36 inches (92 cm) minimum]

 

a vent shall not terminate directly above a sidewalk or paved drive

-

way which is located between two single family dwellings and serves 

both dwellings

   only permitted if veranda, porch, deck, or balcony has an open side 

that is equal to or greater than the depth of the enclosed area

*

   as specified in CGA B149 Installation Codes. Note: local Codes or 

Regulations may require different clearances

Содержание M40DV-CR

Страница 1: ...ead all instructions prior to installation C US Safety Notice Glass doors on gas fireplaces are extremely hot while the fireplaces is on and remain hot even after the fireplace has been turned off Safety screens are available and can reduce the risks of severe burns Please keep children away from the fireplace at all times WARNING Improper installation adjustment alteration service or maintenance ...

Страница 2: ... Indicates a hazardous situation which if not avoided will result in death or serious injury WARNING Indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE Used to address practices not related to personal injury Important Used to address practices not ...

Страница 3: ...ny responsibility for the following actions Modification of the fireplace and or components including Direct Vent assembly or glass doors Use of any component part not manufactured or approved by Montigo in combination with this Montigo fireplace system Installation other than as instructed in this manual Consult your local Gas Inspection Branch on installation require ments for factory built gas ...

Страница 4: ...ed area shown in Figure 20b For protection against freezing temperatures it is recommended that outer walls of the chase be insulated with a vapour barrier This will reduce the possibility of a cold air convection current on the fireplace Figure 2a Framing dimensions Clearances The M40DV CR CL clearances to combustible materials are Top 8 Rear 1 Closed Side 1 Floor Combustible Mantle 6 Flue Cover ...

Страница 5: ...ly piping system during any pressure testing of that system at test pressures in excess of 1 2 psig 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa Installation Vent Installation This section covers the installa...

Страница 6: ...crews 12 12 MSR Figure 4b Installing a PT0 3 termination with the MSR frame Figure 4c Installing a PT0 3 termination with the MOSR frame 12 12 12 MOSR Installing Terminations with MOSR Frames 1 Frame the termination opening to 12 x 12 2 Fasten the MSR frame to the interior side of the studs using a minimum of 4 screws 3 Insert the termination into the MSR frame as shown here and attach by screwing...

Страница 7: ...Acceptable Installation If the vertical dimension from the hearth is 72 and the horizontal run to the wall flange of the vent termination is 36 this would be an acceptable installation Example C Unacceptable Installation If the vertical dimension from the floor of the fireplace is 48 and the horizontal run to the wall flange of the vent termination is 108 this would not be an acceptable installati...

Страница 8: ... Figure 7 Short horizontal installation Figure9 Extendedhorizontalinstallationusingacombinationofrigid and flex venting Figure8 HeatShieldforshorthorizontalinstallation Installbysliding overtheventpipewhereitconnectstothetermination Heat Shields Due to high flue temperatures the heat shield RHS101 must be used on all installations straight through the wall at the point where the vent pipe connects...

Страница 9: ... a clearance of at least 2 2 Offset Vertical Installations Amaximumoftwooffsets eachoffsethastwo90 bends maybe made if the length of the offsets does not exceed 25 of the vertical vent height when measured center to center of piping Example Typical vent installation 30 vertical vent 2 2 offsets required 25 of 30 7 1 2 max offset allowed This venting configuration meets requirements Figure10b Verti...

Страница 10: ...lange of the vent termination is 120 this would be an acceptable installation Example B Acceptable Installation If the vertical dimension from the hearth is 66 and the horizontal run to the wall flange of the vent termination is 30 this would be an acceptable installation Example C Unacceptable Installation If the vertical dimension from the floor of the fireplace is 48 and the horizontal run to t...

Страница 11: ...ve foot chase allow for a maxi mum horizontal run of twelve and one half feet from the centre of the fireplace to outside wall and a minimum of 7 6 when retracted in opposite direction See Figure 14a and 14b D flex sections and E solid sections may be used in conjunction with one another to obtain different possible horizontal length instal lations NOTE Flex section must not exceed maximum horizon...

Страница 12: ...e made if the length of the offsets does not exceed 25 of the vertical vent height when measured center to center of piping Example Typical vent installation 30 vertical vent 2 2 offsets required 25 of 30 7 1 2 max offset allowed This venting configuration meets requirements A Termination PVTK 1 B Flex sections PFL 1 12 section PFL 2 24 section PFL 3 36 section PFL 4 48 section C Solid sections PE...

Страница 13: ...peratures over the mantel will rise above normal room temperature and walls above fireplace may be hot to touch We recommend careful consideration be given to the effects of elevated mantel temperatures which may be in excess of product design for example candles plastic or pictures This can cause melt ing deformation discoloration or premature failure of T V and radio components Painting Figure 2...

Страница 14: ...ide panel by sliding it out and away from the back of the fireplace Refer to figure 22b Removing the Doors Figure 22a Removing the louvre assemblies Figure 22b Removing the side panel To remove the inner doors simply unscrew the eight 8 machine screws on the top and bottom of the door See figure 22c Door Installation To re install the doors align the door with the screw holes and re fasten with al...

Страница 15: ...Place logs C and D into their mating positions on the large logs as shown in Figure 16a below Log E is mounted on top of logs C and D as shown in Figure 23b Warning If logs are not placed properly excessive sooting will result Installing the Ember Material The ember material is supplied in two packages Place the material evenly along both ember burner tubes next to logs A and B Refer to figure 23b...

Страница 16: ...Operation Model M40DV CR CL 3 Push in gas control knob slightly and turn clockwise to Off Do not force 4 Flip up the lower end louvres 1 Turn off remote switch 2 Flip down the lower end louvres 1 STOP Read the safety information above on this label 2 Flip down the lower louvres on the end panel of the fireplace 3 Push in gas control knob and turn clockwise to OFF 4 Wait five 5 minutes to clear out...

Страница 17: ...oor because some gas is heavier than air and will settle on the floor What To Do If You Smell Gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions 1 Turn off remote switch 2 Flip down the lower end louvres Gas Inlet Gas Control Switch Shown in...

Страница 18: ...ou Smell Gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions 1 Turn off remote switch 2 Flip down the lower trims 3 Turn the incoming gas control valve to Off 4 Flip UP the lower trims 1 STOP Read the safety information above on this label 2 ...

Страница 19: ...ng the door as shown on page 9 Handle the door carefully and clean it with an approved glass cleaner One of the most effective products is Kel Kem Silicone seals on inner door during initial firing will off gas leaving a visual deposit of a white substance on combustion chamber walls This can easily be removed by following the steps described below Use a vacuum cleaner or soft bristle brush to kee...

Страница 20: ...l valve Flame is decreased by turning adjustment screw clockwise Pilot won t ignite Disconnect remote wires and try to light pilot If pilot now works remote connections are faulty Check wiring diagram figure 17 Main burner will 1 Check wiring see figure 17 not light 2 Check wall switch for proper con nection 3 Check pilot burner If extinguished a Allow fireplace to cool then try to relight b If co...

Страница 21: ...rious safety hazards may result in the denial of certification by recognized national safety agencies and could be in violation of local building codes This warranty does not cover any damages occurring from the use of any components not manufactured or supplied by The Companies 2 The Montigo Gas Appliance must be subjected to normal use The Gas Appliances are designed to burn gas only Burning con...

Страница 22: ...m in the United States 6 feet 1 8 m minimum in Canada L clearance to nonmechanical air supply inlet to building or the combus tion air inlet to any other appliance 16 inches 41 cm minimum for appliances 100 000 BTU H 30kW M clearance to mechanical air supply inlet 6 feet 1 8 m minimum N clearance above paved sidewalk or a paved driveway located on public property 7 feet 2 1 m minimum P clearance u...

Страница 23: ... in a manufactured or mobile home ThestandardM40DV CR CLortheM40DV CR CL Iequippedwith HotSurfaceIgnition HSI arenotapprovedforuseinmobileor manufactured homes The M40DV CR CL MH is rated for Natural Gas at 30 000 BTU H 8 79 Kilowatts max input and 24 000 BTU H 7 03 Kilowatts min input Propane at 30 000 BTU H 8 79 Kilowatts max input and 24 000 BTU H 7 03 Kilowatts min input Conversion Kits The M4...

Страница 24: ...y in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspection...

Страница 25: ...Page 25 P N XG0206 M40DV CR CL Corner Gas Fireplace Notes ...

Страница 26: ...Canadian Heating Products Inc Langley BC V4W 4A1 Montigo Del Ray Corp Ferndale WA 98248 XG0206 092508 ...

Отзывы: