       WARNING:

FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly could result in serious injury, 

death, or property damage.

— Do not store or use gasoline or other flammable vapors and 

liquids in the vicinity of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.
•  Do not touch any electrical switch; do not use any 

phone in your building.

•  Leave the building immediately.
•  Immediately call your gas supplier from a neighbour's 

phone. Follow the gas supplier’s instructions.

•  If you cannot reach your gas supplier, call the fire 

department.

— Installation and service must be performed by a qualified 

installer, service agency or the gas fitter.

DelRay Square

  

INDOOR DIRECT VENT GAS FIREPLACE

 

DRSQC38NI 

CONTEMPORARY

DRSQC38LI 

CONTEMPORARY

DRSQC38NI-2 

CONTEMPORARY

DRSQC38LI-2 

CONTEMPORARY

DRSQ38NI 

TRADITIONAL

DRSQ38LI 

TRADITIONAL

DRSQ38NI-2 

TRADITIONAL

DRSQ38LI-2 

TRADITIONAL

A barrier designed to reduce the risk of burns 

from the hot viewing glass is provided with this 

appliance and must be installed for the protection 

of children and other at-risk individuals.

HOT GLASS

 WILL CAUSE BURNS.

DO NOT TOUCH

 GLASS UNTIL 

COOLED.

NEVER

 ALLOW CHILDREN  

TO TOUCH GLASS.

DANGER

Installation and service must be performed by a qualified installer, 

service agency or the gas fitter. Check local codes and read all 

instructions prior to installation.

Some materials used in the manufacturing process of this product can 

expose you to Benzene which is known in the State of California to 

cause cancer and birth defects or other reproductive harm. For more 

information go to www.P65warnings.ca.gov

WARNING

Installer:

 Leave this manual with the appliance. Please refer to the 

Montigo website for the most current version of the fireplace manual

Consumer:

 Retain this manual for future reference. Please refer to the 

Montigo website for the most current version of the fireplace manual

NOTICE

Содержание DelRay Square Series

Страница 1: ...38NI TRADITIONAL DRSQ38LI TRADITIONAL DRSQ38NI 2 TRADITIONAL DRSQ38LI 2 TRADITIONAL A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and must be installed for the protection of children and other at risk individuals HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS DANGER Installation and service ...

Страница 2: ...ontigo fireplace system Installation other than as instructed in this manual Consult your local Gas Inspection Branch on installation requirements for factory built gas fireplaces Installation repairs should be done by a qualified contractor Efficiency listing MODEL P 4 1 15 Efficiency DRSQ38NI 63 40 DRSQ38NI 2 64 97 DRSQ38LI 61 82 DRSQ38LI 2 61 54 DRSQC38NI 63 40 DRSQC38NI 2 64 97 DRSQC38LI 61 82...

Страница 3: ...GAS CONNECTION 21 Finishing Safety Zone 21 Section 6 Finishing 22 Finishing Around the Fireplace 22 Sidewall clearances 22 Cement Board Install 22 Elevated surface temperatures 23 Standard installation 23 Venting ports open w vented chase 23 Heat distribution kit installed 23 Section 8 Removing Installing the Screen Door 24 Removing the Screen 24 Reinstalling the Screen 24 Removing the door 24 Rei...

Страница 4: ...Z223 1 NFPA 54 Electrical installations must conform to the local codes or in the absence of local codes to the current version of the National Electrical Code ANSI NFPA 70 See Appendix C for installation within the State of Massachusetts Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of th...

Страница 5: ...nce Firestops installed Exteriorwall roofflashinginstalledandsealedincompliancewithlocalbuildingcode Terminations installed and sealed in compliance with local building code Direct vent termination is highest point in vent assembly Wiring Electrical Section 4 Unswitched power provided to the appliance PPO box Low voltage wire connected to dry contact wall switch non powered Gas Section 5 Proper ap...

Страница 6: ...as Fireplace Heater For Indoor Use Only Clearance to Combustibles Not for use with solid fuel Pas pour l usage avec le combustible solide Degagements Aux Combustibles Serial No N H 0 4500 ft 0 1371 m Max Input Min Input Output Orifice Size Taille D Orifice Gas Manifold Max Entrée Min Entrée Rendement Front Avant Rear Derrière Pressure Pression BTU H BTU H BTU H D Admission Du Gaz X 24 000 16 500 N...

Страница 7: ...6 1 2 POWER SUPPLY GAS SUPPLY Screen I D opening Fireplace I D opening TOP OR REAR VENT REVISIONS REV DESCRIPTION DATE CHANGED BY 1 16 DWG NO SHEET 2 OF WEIGHT DRSQ38 Full Assembly Finish MATERIAL DIMENSIONS ARE IN INCHES TOLERANCES FRACTIONAL 1 32 TWO PLACE DECIMAL 015 THREE PLACE DECIMAL 005 ANGULAR 5 ALL BENDS ARE ASSUMED TO BE 90 UNLESS NOTED OTHERWISE Revision Date Drawn by DATE NAME 25 10 20...

Страница 8: ...ND CONFIDENTIAL Y Products Residential Products R D Projects DelRay DelRay Square DelRay38 Cad Drawings DRSQ38 Rear Vent Chase Full Assembly May 15 20 7 53 41 AM SCALE DM Description DRSQ38 Venting Assembly Revision DIMENSIONS ARE IN INCHES TOLERANCES FRACTIONAL 1 32 TWO PLACE DECIMAL 015 THREE PLACE DECIMAL 005 ANGULAR 5 ALL BENDS ARE ASSUMED TO BE 90 UNLESS NOTED OTHERWISE MIN 59 1 MIN 8 1 2 14 ...

Страница 9: ...se contact your Montigo dealer to discuss power venting options Notes For Planning Venting Venting originates from the top or rear of the unit Venting can terminate through the roof or through an exterior wall Refer to Appendix A Termination Locations to ensure the planned termination location is acceptable Once the termination location has been established refer to the appropriate section below f...

Страница 10: ...installation check primary air opening below are factory settings DRSQ38 I 3 16 for NG and for Propane DRSQ38 I 2 for NG and full open for Propane Theprimaryairmightneedadjustingfromthefactorysettingforvertical runs If flame is sooting primary air may need to be opened slightly Smaller primary air opening means yellower flame Note all adjustments to primary air must be made by qualified installers...

Страница 11: ...owed is 32 ft V max Maximum horizontal run allowed is 25 ft H max DRSQ38 5 8 TOP Venting Wall and roof termination Maximum total vent run allowed is 34 ft V H 34ft For longer vent runs a power vent is required V H are measured from the center of vent elbows Elbow may be attached directly to the top of the unit Maximum vertical run allowed is 32 ft V max Maximum horizontal run allowed is 25 ft H ma...

Страница 12: ...o suit Slide the fireplace into position and attach to the termination 45 or less Corner Installation 5 8 Use an PTO 4 termination and an PFL 1 or PFL 2 PFL 2 12 or 24 compressed length and a frame if appropriate Flex may be turned to obtain desired degree of angle required but must not exceed 45 PVK05 kit can be also be used NOTE The PVK05 PVK05F kit is available for top vent corner FLEX applicat...

Страница 13: ...ts each offset is made up of 2 90 bends may be made for vertical vent runs Firestops must be installed as required by National local codes Ensure all horizontal runs are supported with a minimum of 3 supports per 10 of venting Install all roof flashing and storm collars as shown Figure 6 Top vent roof mounted termi nation with no offset in vent run Figure 6 b Top vent Roof mounted with 1 offset 1 ...

Страница 14: ...erior side of the studs concrete or finished wall construction using a minimum of 4 screws 3 Insert the termination into the MOSR frame as shown here from the inside and attach to the MOSR by installing a min quantity of 4 bolts into the threaded nuts on the MOSR Frame Installation of termination frame at time of framing in masonry Terminations with a BSR frame allow the installation of the frame ...

Страница 15: ...uilding Envelope Engineer or Waterproofing Consultant for further recommendations IMPORTANT Please refer to your Building Envelope Engineer or Waterproofing Consultant for a review of ALL penetrations through exterior walls or the roof Figure 7 Flue cover and collar removal and install Top Vented fireplace Montigo supplies a variety of direct venting and termination options Thedirectventterminatio...

Страница 16: ...2 58DVA 16A 20 5DLT 12 5DLS1 12 5DLT2 20 5DSL2 20 5DAL 3 to 10 5DT AJ12 12 Rigid Telescopic Pipe 58DVA 17TA 58DVA 24TA 5DLA30 Elbows 5 8 Vent PEL 90MM m m 90º PEL 90FF f f 90º PEL 90FM f m 90º PEL 45FM f m 45º 58DVA E30 30 58DVA E45 45 58DVA E60 60 58DVA E90 90 5DE45 45 5DE90 90 5D45L 45 5D90L 90 5DT EL45 45 5DT EL90 90 Support Ring Plate PSPXT 8 58DVA DC 5CS 5DT CS Firestop FS 8 58DVA WFS 58DVA F...

Страница 17: ...1 5 4DVKIT4702 4DVKIT4703 4DVKIT4704 4DVKIT4706 Rigid Pipe MEXT 1 12 f m Section MEXT 2 24 f m Section MEXT 3 36 f m Section MEXT 4 48 f m Section MEXT 6 72 f m Section 46DVA 06 6 Section 46DVA 09 9 Section 46DVA 12 12 Section 46DVA 18 18 Section 46DVA 24 24 Section 46DVA 36 36 Section 46DVA 48 48 Section 46DVA 60 60 Section Rigid Pipe Extension EXT18 18 f f Section 46DVA 08A 8 Length 46DVA 16A 16...

Страница 18: ...rock Drywall sheetrock RHS10 Heat Shield inner Section RHS10 Heat Shield inner Section Vent pipe from fireplace Vent pipe from fireplace Combustible framing Combustible framing Combustible framing RHS10 Heat Shield Outer Section RHS10 Heat Shield Outer Section Termination Termination 3 8 min Inner shield Outer shield A A B Installing the included heat shield The included Heat shield CANNOT be used...

Страница 19: ...onal Electrical Code ANSI NFPA 70 Optional remote control available through your Montigo Dealer DRSQ N L I Wiring Diagram BLACK WHITE GREEN To PPO SPARK SENSOR TO ON OFF WALL SWITCH YELLOW GREEN ORANGE GREEN 6 10 OPTIONAL CPI IPI SWITCH BLUE WHITE X1 X5 X4 X3 X2 3 15A FUSE BLUE RE Figure 15 Wiring diagram for DRSQ38 I with SIT Proflame Electronic Ignition Section 4 Wiring MODEL DRSQ38NI DRSQC38NI ...

Страница 20: ... N L I 2 Wiring Diagram 1 5V AA type 1 5V AA type 1 5V AA type 1 5V AA type WHITE BLACK BLACK WHITE GREEN Lights ON OFF CONTROL MAIN Power 120VAC 60 Hz 6 Amps SPARK SENSOR RED BLACK BATTERY PACK MAIN ON OFF SWITCH YELLOW GREEN PILOT R ORANGE GREEN BLACK BROWN YELLOW ORANGE 6 10 6 OPTIONAL CPI IPI SWITCH WHITE LED Lights LED1 Red LED LED2 Amber LED SW1 LED o tro e r LED power s pp y white white whi...

Страница 21: ...nnect incoming gas line to the 1 2 or 3 8 gas inlet port Check appliance connection valve and valve train under normal operatingpressurewithacommerciallyavailableleakchecksolution DO NOT USE A FLAME OF ANY KIND TO TEST FOR LEAKS PRESSURE REQUIREMENTS Gas Pressure Natural Gas Propane Minimum inlet pressure 5 5in w c 11in w c Manifold pressure 3 5in w c 10in w c Section 5 Installing the gas line Aft...

Страница 22: ...earances Edge of fireplace Sidewall TOP OF UNIT Sidewall clearances Side wall clearances are 4 Combustible surrounds may be installed with 4 clearance to the side of the fireplace as shown 4 clearance in sidewall drawing does not apply to recession unit cannot be recessed into a wall NOTICE 4 Min Combustible Mantle Height from fireplace opening 6 Combustible Mantle Depth 11 1 2 3 4 5 6 7 8 9 10 11...

Страница 23: ...ze IMPORTANT Leaving the venting ports open requires a minimum chase heightof8 andachaseopening of at least 100 inches VENTED CHASE Minimum 100 inches opening and 8 chase IMPORTANT Heat distribution kits can be either the form of a sidewall kit or a TV kit Both require HDKPDFK 1 5 flex kit 12 length Combustible surround flush to opening requires standard cement board Combustible surround flush to ...

Страница 24: ...liance Figure 20 Locate the three tabs at the base of the screen Figure 20 b Lift out the Retaining Tabs and screen NOTICE STEP 1 Remove lower valve blinds and screen setting bar STEP 2 Ensure the tool is firmly in the lower end of the slot as shown Then pull toward you door will unlatch repeat for other buckle STEP 2 Buckles are locked into place by pulling out and up latch will pop into place ST...

Страница 25: ...s included in package 5 Using a Philips screwdriver loosen the screw on the primary air adjuster Adjust opening to if you have a DRSQ38NI and using the conversion kit GCA020 Adjust opening to fully open if you have a DRSQ38NI 2 and using the conversion kit GCA021 Propane Conversion Tools required 1 Torx T20 Screw Driver Bit 2 1 2 Socket Driver 3 5 32 Allen Key 4 Needle Nose Pliers or Small Flat He...

Страница 26: ...e conversion label on valve face 10 If necessary pilot flame size can be adjusted using a flathead screwdriver to adjust pilADJ screw shown 9 See regulator instructions for guide on converting the pressure regulator gasket 11 The manifold and inlet pressure can be verified by using a manometer and a 1 8 rubber hose attached to the valve ports shown here top is manifold bottom is inlet Use a soap b...

Страница 27: ...burners Note Only cover the burner with one layer The DelRay Square transitional burner The burner for the DelRay Square has been developed in away that equally supports contemporary and traditional scenes without the need for a burner swap Installing a contemporary scene glass and stone The combination of a glass firebed with stones places around the burner ports provide the best contemporary bur...

Страница 28: ...end resting on log A Step 6 Rest log F on logs E and D Step 3 Place log C behind the pilot with the charred end wrapping around to the center of the tray Step 7 Place log G on the lower section of log D with the other end resting in the base media Step 4 The cut end of log D points towards the front right corner of the firebox with the other end resting on log B Step 8 the y split end of log H res...

Страница 29: ... delayed ignition DO NOT cover the pilot with logs WARNING This appliance is intended for use only with the included Montigo burners and accessories Never install or add any additional or alternative media rock wool or other material in this appliance The use of additional or alternative materials may pose potential safety hazards damage to the appliance and void manufacturer s warranty Step 9 Log...

Страница 30: ...e to the appliance and void manufacturer s warranty Birch Logset Installation Step 1 Log A is placed at the rear center of the media tray Step 5 Log E is placed diagonally directly in front of log B Step 2 Log B is placed at the right corner of the firebox with the charred side facing the middle of the media tray Step 6 Rest log F horizontally between logs C and E Step 3 Place log C at the left co...

Страница 31: ...on log E with the other end resting in the middle of the tray Step 4 Log D is placed in front of the pilot underneath log C A B D E F G C Only cover the burner with one layer of coals Arrange the ember chips on top of the burner tray DO NOT cover the pilot with logs WARNING This appliance is intended for use only with the included Montigo burners and accessories Never install or add any additional...

Страница 32: ...tep 4 Bend the left side tab on the bracket Place right side glass in place and secure with the bracket using screw Bend the right side tab on the bracket Place left side glass in place and secure with the bracket using screw Step 5 It is now safe to remove the masking tape Figure 20 b Remove the two screws Figure 20 b hold it in place using masking tape Figure 20 b Bend the left side tab Figure 2...

Страница 33: ...t in place or use masking tape Don t use regular tape as it will leave residue on the panel Step 3 Use the included clips to secure right panel into the screw hole referenced in step 1 Step 4 Install left panel using same steps in step 3 Step5 Itisnowsafetolettherearpanelbesupportedbythesidepanels Figure 20 b Remove the two screws Figure 20 b hold in place or secure using masking tape Figure 20 b ...

Страница 34: ...Manifold Pressure Test Connection Pilot Adjustment Screw Inlet Pressure Test Connection Output Regulator Control Optional A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and must be installed for the protection of children and other at risk individuals HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH ...

Страница 35: ...sual deposit of a white substance on combustion chamber walls This can easily be removed using normal household products Use a vacuum cleaner or whisk broom to keep the control compartment burner and firebox free from dust and lint Figure 28 Pilot Adjustment on the SIT Proflame 2 gas valve Pilot Burner Adjustment 1 Locate Pilot Adjustment Screw See figure 28 2 Adjust pilot screw to provide properl...

Страница 36: ...ng fireplace penetration of an exterior building envelope Dimension A X 75 min overhang depth The overhang must extend at least 75 of the roof line height A Height is measured from bottom of fireplace opening to the ceiling Follow all product installation instructions including framing clearances to combustibles mantel heights Facing Requirements venting installation etc Use supplied safety screen...

Страница 37: ...mbustion air inlet to other appliance for appliance 100 000 BTU H 30 KW 12 inches 12 inches M clearance to forced air supply inlet 6 feet 3 feet above air inlet N clearance above paved sidewalk or paved driveway located on public property 7 feet 7 feet P clearance under veranda porch deck or balcony 22 inches to combustibles 16 inches to non combustibles 22 inches to combustibles 16 inches to non ...

Страница 38: ...um LP only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the appliance produce excessive temperatures will result in a fire hazard and void all warranties This warranty is transferable The appliance must remain in its original place of installation to be valid If the components of the appliance covered by this warranty are found to be defective...

Страница 39: ...ritten consent of The Companies The Companies shall in no event be responsible for any warranty work done without first obtaining the Companies written consent The Companies employees and dealers have no authority to make any warranties to neither alter this warranty nor authorize any remedies in addition to or inconsistent with those stated within this warranty IF WARRANTY SERVICE IS NEEDED To ma...

Страница 40: ...The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS Appendix C Amendment Gas Fireplace Equipment sold in the State of Massachusetts 5 08 Modifications to NFPA 54 Chapter 10 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon ...

Страница 41: ...41 Notes XG0230 052020 ...

Страница 42: ...XG0230 052020 Installation Maintenance Manual DelRay Square Single Sided Gas Fireplace ...

Отзывы: