Section 3: Installation Location

Montigo reccommends that you install the Custom 

C-View Firepit in an exterior area that is not cov-

ered. This will ensure no collection of off gases.

Should you be installing the firepit in a covered 

area, you must abide by the following requirements.

en

en

Acceptable Installation 1

Install Firepit under a covered area with 3 sides open

en

Acceptable Installation 2

Install Firepit under a covered area with 2 sides open

Acceptable Installation 3

For covered area installations where less than 2 sides 

will be fully open, there must be one side open such 

that there is 10 square feet of fresh air per 20,000 BTU 

of your unit. Also you must install a Montigo interlocking 

carbon monoxide detector in the furthest location from 

the opening. (Part No. EBOX-A310)

Fig 2: Covered Installation Option 1

Fig 3: Covered Installation Option 2

Fig 4: Covered Installation Option 3

Clearances to Surrounding Construction

Clearances to the ceiling of the space and to adjacent walls must meet requirements shown below:

Wall

Model

Y

Y1

CFPO-2

6'

7'

CFPO-3

7'

8'

CFPO-4

8'

9'

CFPO-5

9'

10'

CFPO-6

10'

11'

CFPO-7

11'

12'

CFPO-8

12'

13'

CFPO-9

13'

14'

CFPO-10

14'

15'

Fig 5: Clearance to Surrounds

Page 5

XG0702 

Custom C-View Fireplace

Installation

Содержание CFPO-10

Страница 1: ...ks Danger overhead crane Explosion risk Oxidising Danger of death Biohazard Laser Radiation Danger of entrapment Hot surface General Warning Blank Gas bottles Watch for falling objects Electricity Danger for cutter Entrapment hazard Battery hazard Rotating parts Low temperature Strong magnetic field Optical radiation Non ionizing radiation Radiation Hazardous to the Environment Danger of harming y...

Страница 2: ... 9 Installing the Gas Line 11 Section 10 Installing the Burner Accessories 12 Installing the Firestones 12 Operation 13 Section 11 Start Up 13 Maintenance 14 Section 12 General Maintenance and Cleaning 14 Annual Inspection Checklist 14 Section 13 Troubleshooting 15 Appendix 16 Appendix A Warranty 16 Appendix B State of Massachusetts 17 Page 2 Table of Contents Custom C View Fireplace XG0702 You mu...

Страница 3: ...maintenance Lighting operation and care of this fireplace can be easily per formed by the end user All installation and service work should be performed by a qualified or licensed installer plumber or gas fitter as certified by the state province region or governing body where the fireplace is being installed Thisinstallation operationandmaintenancemanualisapplicable tothemodelsdescribedbelow Refe...

Страница 4: ...ot covered however if you wish to place it in a covered area there are strict guidelines that must be adhered to in Section 3 Place the unit in a location that is least affected by wind Firepits have an open flame that can cause injury Consider the safety of children and other indi viduals during placement Montigo requires that all framing in direct contact with the unit be of non combustible cons...

Страница 5: ...ss than 2 sides will be fully open there must be one side open such that there is 10 square feet of fresh air per 20 000 BTU of your unit Also you must install a Montigo interlocking carbon monoxide detector in the furthest location from the opening Part No EBOX A310 Fig 2 Covered Installation Option 1 Fig 3 Covered Installation Option 2 Fig 4 Covered Installation Option 3 Clearances to Surroundin...

Страница 6: ...underneath by non combus tible framing spaced no more than two feet apart Do not support the firepit by its surrounding lip Additionally ensure that all surrounding materials are non combustible or follow the clearances to combustibles given in this manual The inner dimensions of your surround framing are recom mended to be Dimension G Fig 6 plus 1 inch by Dimension C Fig 6 plus 1 inch This will g...

Страница 7: ... CFPO 9 26 65 CFPO 10 30 00 Section 6 Combustion Air Supply Fresh Air Supply Grille Fig 9 Fresh Air Supply Grille Non Combustible Surround Fig 8 Framing Diagram Gas In Fresh Intake Air Min 3 From Bottom of Cross Supports to Floor 6 Clearance Shown Here 1 Min Clearance to Non Combusti ble Materials All Around 4 x 18 Screened Opening Shown Here Do Not Install Cross Supports Directly In Line with Int...

Страница 8: ... Single Phase 110 Volt AC 5 Amp NEMA 5 15P Power Output from Transformer 24VAC 40VA Max Gas Valve Firepit On Off Switch Plug Black Black Red Red Black White Green 110V 24V 6 375 7 875 8 5 8 5 4 625 Replacement Parts available from your local Montigo dealer Section 7 Electrical Control Panel This control panel will be used for units with 1 gas valve including CFPO 2 CFPO 3 CFPO 4 CFPO 5 CFPO 6 CFPO...

Страница 9: ...upply Single Phase 110 Volt AC 5 Amp NEMA 5 15P Power Output from Transformers 24VAC 40VA Max Gas Valve 1 Firepit On Off Switch Plug 110V 24V 24V 110V Gas Valve 2 Black Black Red Red Black White Green Brown Red 6 375 7 875 8 5 8 5 4 625 Replacement Parts available from your local Montigo dealer This control panel will be used for units with 2 gas valve including CFPO 9 CFPO 10 and larger custom si...

Страница 10: ...e glow plug will light the pilot and establish a pilot flame The pilot flame is recognized by the flame sensor rod and sends a signal to the valve to open the main burner Any distortion of the flame pattern will give the valve a faulty signal and turn the main burner off If the air movement of the system is too erratic the air may move the pilot flame from the sensor rod and turn the valve off Aft...

Страница 11: ...the floor because some gas is heavier than air and will settle on the floor What To Do If You Smell Gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life The gas connection is located on the underside...

Страница 12: ... across the pan and the burners as described in Figure 14 to 14d Note Only cover the burner with one layer of designer fire stones Figure 14 Installation of the firestones Ensure ONLY one layer of firestones cover the surface Figure 14a Spreading the firestones evenly and make sure there are no firestones covering the pilot Figure 14b Completed firestone installation Figure 14c Completed firestone...

Страница 13: ... mounted on the side of the control panel 3 The control panel will supply power to the Honeywell smart valve The glow plug will light the pilot and establish a pilot flame The pilot flame is recognized by the flame sensor rod and sends a signal to the valve to open the main burner Any distortion of the flame pattern will give the valve a faulty signal and turn the main burner off If the air moveme...

Страница 14: ...shed when cleaning appliance General Have the firepit installation inspected yearly including a visual check of the vent system the burner and the pilot flame For your convenience a 1 8 manifold pressure tap is supplied on the gas valve for a test gauge connec tion For Natural Gas this appliance requires a minimum inlet pressure of 5 5 wc and a manifold pressure of 3 5 wc For Propane this applianc...

Страница 15: ... Support Yes 1 minute system purge Smart valve relay on Hot surface igniter glows No Yes Pressure switch trip Failed purge timer Yes Pilot flame lights No Control cable not connected Pilot assembly failure Smart valve failure No Air in gas line Gas not turned on Yes Igniter off Smart valve opens Main burner lights No Pilot not touching flame rod Poor ground connection Turn wall switch off Fireplac...

Страница 16: ...nly Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability It is expressly agreed and understood that The Companies sole obligation and purchaser s exclusive remedy under this Warranty under any other warranty expressed or implied or in contra...

Страница 17: ...horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspection the inspector observes carbon monoxide detectors...

Страница 18: ...Ferndale Washington TF 1 800 789 6236 FX 1 866 3000 0927 XG702 092711 Langley British Columbia TF 1 800 378 3115 FX 1 604 607 6462 CFPO Custom Outdoor Firepit ...

Отзывы: