background image

10/92

Page # 1 of 6

M36SR

INSTALLING AND OPERATING

YOUR MONTIGO

GAS-BURNING FIREPLACE

Please leave this manual with the owner

CHECK LOCAL CODES PRIOR TO INSTALLATION

FOR YOUR SAFETY

FOR YOUR SAFETY:

IF  YOU SMELL GAS:

1. OPEN WINDOWS.

DO NOT STORE OR USE ANY FLAMMABLE

2. DON'T TOUCH ELECTRICAL SWITCHES.

VAPOURS OR LIQUIDS NEAR THIS OR ANY

3. EXTINGUISH ANY OPEN FLAME.

OTHER GAS-BURNING APPLIANCE.

4. IMMEDIATELY CALL YOUR GAS SUPPLIER.

READ INSTRUCTIONS CAREFULLY BEFORE INSTALLING

MODEL

MONTIGO 36SR

CANADIAN HEATING PRODUCTS INC.

12091 88th Avenue, Surrey, B.C. Canada  V3W 3J5  Ph #: (604) 597-3115  Fax #: (604) 597-3096

Содержание 36SR

Страница 1: ...F YOU SMELL GAS 1 OPEN WINDOWS DO NOT STORE OR USE ANY FLAMMABLE 2 DON T TOUCH ELECTRICAL SWITCHES VAPOURS OR LIQUIDS NEAR THIS OR ANY 3 EXTINGUISH ANY OPEN FLAME OTHER GAS BURNING APPLIANCE 4 IMMEDIATELY CALL YOUR GAS SUPPLIER READ INSTRUCTIONS CAREFULLY BEFORE INSTALLING MODEL MONTIGO 36SR CANADIAN HEATING PRODUCTS INC 12091 88th Avenue Surrey B C Canada V3W 3J5 Ph 604 597 3115 Fax 604 597 3096 ...

Страница 2: ...and offers an accessible pathway for B Vent installation The fireplace dimensions are shown below NOTE these are not framing dimensions see Figure 2 for framing dimensions FIGURE 1 FIREPLACE DIMENSIONS 36 20 1 4 36 4 21 3 4 68 48 39 4 1 2 Sq 19 1 2 32 1 8 12 1 2 26 1 4 11 CAUTIONS Due to its high operating temperatures the appliance should be located out of traffic away from furniture and draperie...

Страница 3: ... B Vent to the L shaped brackets on each side of the opening with 1 4 sheet metal screws Do not penetrate the inner sleeve of the B Vent when tightening the screws Refer to the current CAN CGA B 149 Gas Installation Code for specific vent sizing installation instructions The following table is provided as a guide for types of B Vent to use with common installations These values have been formulate...

Страница 4: ...at allowing a longer time to elapse before releasing dial d To light the main burner turn dial to ON then turn on remote switch e Turn off flame with remote switch For complete shut down slightly depress gas control valve dial and turn to OFF position To Power Pile To Switch Pilot Adjustment Cap 1 8 N P T Pressure Tap MAINTENANCE Have the fireplace installation inspected yearly including a visual ...

Страница 5: ...ure 8 FIGURE 7 BIFOLD DOOR MOUNTING To install the door kit in the Montigo 36SR a To install left door place bottom pivot into bottom door hole Push top spring clip upwards using a screwdriver and snap top pivot into top spring clip hole Repeat above procedure to install right door b Doors may be adjusted by simply loosening spring clip screw and adjusting door into square c Doors may be adjusted ...

Страница 6: ...ted to normal use The decorative gas appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the decorative gas appliance will produce excessive temperatures and will result in a fire hazard LIMITATIONS ON LIABILITY It is expressly agreed and understood that Canadian Heating Products Inc s sole obligation and Purc...