3.10.
Connecting and Setting the Proximity Switches
The inductive proximity switches may not be set before the stroke limitation has been finalized.
The proximity switches used must have a switching distance (Sn) of 2 mm, be intended for flush mounting
and have a casing 6.5 mm in diameter.
Setting procedure (Jaws open/closed)
Setting procedure (Jaws open)
–
Open the jaws.
–
Insert proximity switch (i1) in clamping sleeve (430) and together with the sleeve push in as far as
the stop.
–
Lightly secure the proximity switch with set-screw (360).
Setting procedure (Jaws closed)
–
Close the jaws.
–
Insert proximity switch (i2) in clamping sleeve (430) and together with the sleeve push in as far as
the stop.
–
Lightly secure the proximity switch with set-screw (360).
360
360
430
430
LED
LED
i
2
i
1
Jaws closed
Jaws open