For Canadian installation in both flush and down-
rod mode the safety cable must be installed into
the house structure beams using the 3” lag screws
provided. Make sure that when the safety cable is
fully extended the leadwires are longer than the
cable and no stress is placed on the leadwires.
Hang assembled fan from the mounting bracket
installed to ceiling in previous step. Make sure the
fan is hanging straight. Rotate fan until the tab on
the Mounting bracket engages the slot on the
Downrod Ball. This must be done to prevent the fan
body from rotating when the blades are in motion.
10
11
Make wire connections to power source using wire nuts
provided. Make sure that no filiments are outside of
the wirenut. After making the wire connections, the
wires should be spread apart with the grounded con-
ductor and the equipment-grounding conductor on one
side of the outlet box and ungrounded conductor on
the other side of the outlet box.
Canadian mounting only
Safety Cable
Lag Screw
16
Lag Screw
Washer
Lock Washer
Safety Cable
Place blade holders onto blades aligning holes
in blade holder with holes in blade. Make sure
that the side of the blade you select is facing
downward. Install 3 screws and fiber wash-
ers to back side of blade as shown. Tighten
screws securely. Repeat this process 4 more
times until all blades are assembled.
18
Set dip switches on the Remote Transmitter and Remote
Receiver to the same settings. This must be done so the
units will communcate properly. If you have other fans you
can set to control from one transmitter by setting both
receivers the same as the transmitter. If you have more
than one fan with remote. You can set the dip switches to
different positiosns to have seperate control.
Remote Transmitter Dip swtiches
Remote Receiver Dip switches
12
Install remote receiver into the
mounting bracket.
13
Ready for wiring.
14
white
black
Make wiring connections as indicated above.
White from fan to white from remote marked
N. Blue from fan to blue from remote marked
light. Black from fan to Black from remote
marked L. White from house to white from
remote marked AC N . Black from house to
Black from remote marked AC L. Connect all
green ground wires to Ground wire from
House.
blue
Green
white
black
House
Fan
15
fuses
Lift canopy and install knurled nuts as
shown. Tighten the knurled nuts securely.
The canopy should adjust for any irregu-
larity in the ceiling or Outlet box.
17
Loosen the 2 set screws in yoke for
downrod to slip into yoke. Insert
downrod into yoke on top of the Fan
Body. Align the hole in the Downrod
with the hole in the Yoke. Insert the
Pin through the Yoke and Downrod
until the point appears on the other
side. Install the Keeper Pin
Tighten the 2 Set screws on the Yoke
once the downrod is in place.
8
9
Yoke
Cross Pin
Keeper
Pin
Thread canopy and yoke cover on down-
rod, Thread leadwires and safety cable
through the downrod.
Follow inserts as
shown above.
7
Canopy
Yoke cover
downrod
Ball