REMOTE CONTROL SETTING and OPERATION

Universal Mode and Learning Mode

There are “Universal Mode” and “Learning Mode” with the remote controller. 
If choosing “

Universal Mode

”, simply place dip (code) switch at UPPER 

position. Your fan with the remote controller is ready to use. 

Note

: If using universal mode, your fan can be controlled with other remote 

transmitters with the same setting.
To control the fan with specific remote transmitter, choose “

Learning Mode

” 

by placing the dip (code) switch at LOWER position and then make learn 

function setting as below. 

Learn function setting

, Restore power source to your fan, press and hold 

the “

LEARN

” button for at least 3 seconds. You must press the “

LEARN

” 

button within 60 seconds of restoring power to the fan.

Note

: If the power is on already, you must turn the power off for 10 seconds 

at least, and then turn the power back for remote control learn function 

setting. 

Note

: If the fan is installed with light, light will twinkle 2 times. The remote 

control setting process is complete and your fan is ready for use. For fans 

without light, check operation using remote transmitter. 

Note

: If you want to control the fan with another transmitter, make the same 

setting. A fan can be controlled by 2 transmitters maximum.

Transmitter Operation  

Remove the battery cover from the remote control transmitter and install 

battery, battery provided. Replace the cover.

Note

: Use 2 1.5V/AAA 

 

battery. 

Note

: If not using for long period of time, remove battery to prevent damage 

to remote transmitter, and store the remote transmitter away from excess 

heat or humidity.

ON

DIM

LE

AR

N

L.CODE

COMMON

CODE

L.CODE

COMMON

CODE

ON

DIM

Universal Mold 

Learning Mold

Dimming / Non Dimming Setting

The “DIM” selection is the light dimmable selection and the light will cycle 

from bright to dim to bright until button is released. The “ON” selection is the 

light ON/OFF only (non dimming function). Light will maintain last setting if 

turned off.

Note

: The remote controller is set with dimming function at factory,

 

Note

: If the remote receiver has been wired with fan, turn power off by wall 

switch before switch “DIM” and “ON/OFF” selection.  

Dimming/

Non dimming

LEARN

Learn

The receiver provides the following protective functions

Lock protection- The DC motor has a build-in safety feature against blade or motor obstruction during operation. If 

something obstructs the fan blades or motor, the motor will keep trying to run for 5 times and then stop operation 

after about 60 seconds of interruption. Please remove obstacles and reset. To reset it by turn the fan off by remote 

transmitter and then turn the fan on, Or you may turn power off for 15 seconds then turn power back, and then turn 

the fan on,    

Over load protection (current limit)- The device will limits the maximum current output from the receiver/drive when the 

fan or light load was increased abnormally. 

Содержание 5LLR56

Страница 1: ...F PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com 5LLR56XXD Series Fan ETL Model NO 5LLR56 XXXXX 8 kgs 17 6 lbs 3 0 6 4 9 6 4 ...

Страница 2: ...o Not Remove Knockouts In The Outlet Box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building structure or the ceiling joist Attach the mounting bracket using only the hardware supplied with the outlet box WARNING To Reduce The Risk Of Electric Shock This Fan Must Be Installed With a general use isolating Wall Control Switch WARNING To red...

Страница 3: ...bs Use metal outlet box suitable for fan support and use only the screws provided with the outlet box must support 35 lbs Before attaching fan to outlet box ensure the outlet box is securely fastened by at least two points to a structural ceiling member a loose box will cause the fan to wobble Remove the two outlet box screws provided with the box aligning the holes of the mounting bracket with th...

Страница 4: ...ructure beams using 1 5 lag screws washers and lock washers provided Make sure that when the safety cable is fully extended the lead wires are longer than the cable and no stress is placed on the lead wires Note If Installing The Secondary Support Safety Cable in the U S Do Not Remove Knockouts In The Outlet Box Make wiring connections using wire connectors provided as indicated above Red from fan...

Страница 5: ...ne of non slotted holes on the rim of the canopy For Canadian installation and for USA fan and light kit combinations over 35 lbs in both flush and downrod modes the safety cable must be installed into the house structure beams using 1 5 lag screws washers and lock washers provided Make sure that when the safety cable is fully extended the lead wires are longer than the cable and no stress is plac...

Страница 6: ...ding to the slotted holes on the canopy upper ring Remove the other 2 set screws Save screws Raise canopy to mounting bracket aligning loosened screws in mounting bracket with slotted holes in canopy Twist canopy to lock Reinstall the screws removed in step 18 and tighten all screws securely Align the holes of blade bracket blade and the top plate of blade bracket Install blade bracket with blade ...

Страница 7: ...e wire from fan to blue wire from light fixture Attach light fixture onto the light plate aligning keyhole slots on the light fixture with the preassembled set screws on light plate and twist clockwise until lock Reinstall the screw removed in step 23 Tighten all screws securely Place glass over glass fixed ring aligning the thread on light fixture and attach it onto light fixture by turning clock...

Страница 8: ...mote control transmitter and install battery battery provided Replace the cover Note Use 2 1 5V AAA battery Note If not using for long period of time remove battery to prevent damage to remote transmitter and store the remote transmitter away from excess heat or humidity ON DIM LEARN L CODE COMMON CODE L CODE COMMON CODE ON DIM Universal Mold Learning Mold Dimming Non Dimming Setting The DIM selec...

Страница 9: ...leased Note This remote controller has auto resume function the fan and light will maintain the last setting if power is turned off Tips for end users 1 If your fan is operated automatically after installation and power on it is because your fan is still memorize the previous setting at factory 2 If fan or light isn t working reset power turn the power off for at least 10 seconds and then turn the...

Страница 10: ...N LQ SHULRG RI KRXUV 0RVW QRLVHV DVVRFLDWHG ZLWK D QHZ IDQ ZLOO GLVDSSHDU DIWHU WKLV SHULRG I WKLV LV D GRZQURG PRXQW IDQ PDNH VXUH WKH ULGJH RQ PRXQWLQJ EUDFNHW HQJDJHV WKH QRWFK LQ WKH GRZQURG EDOO 0DNH VXUH WKDW FDQRS PRXQWLQJ EUDFNHW RU PRXQWLQJ SODWH DUH WLJKWHQHG VHFXUHO WR FHLOLQJ MXQFWLRQ ER DQG MXQFWLRQ ER LV PRXQWHG UPO WR FHLOLQJ MRLVW KHFN WKDW DOO EODGHV DUH VFUHZHG UPO LQWR EODGH KRO...

Страница 11: ...Oct 2014 ...

Отзывы: