background image

3

© 2014 Monte Carlo Fan Company

10/1/2014

1

2

3

4

5

6

ON

OFF

ON

OFF

Before you begin installing the fan, Switch 

power off at Service panel and lock 

service disconnecting means to prevent 

power from being switched on 

accidentally. When the service 

disconnecting means cannot be locked, 

securely fasten a warning device, such  

as a tag, to the service panel.

Use AC 120V/60HZ power supply 

only.

Before installing this fan make sure the 

outlet box is properly installed to the 

house structure. To reduce the risk of 

fire, electric shock, or personal injury, 

mount to outlet box or supporting system 

acceptable for fan support. 

(Mounting must support at least 35 lbs.)

Use metal outlet box suitable for fan 

support and use only the screws provided 

with the outlet box  (must support 35 

lbs). Before attaching fan to outlet box, 

ensure the outlet box is securely fastened 

by at least two points to a structural 

ceiling member (a loose box will cause 

the fan to wobble). Remove the two outlet 

box screws provided with the box, 

aligning the holes of the mounting 

bracket with the holes of the outlet box. 

Reinstall the 2 outlet box screws 

securely.

Remove preassembled keeper pin and 

cross pin from downrod.

Place downrod over canopy and yoke 

cover

Partially loosen downrod set screws from 

yoke at top of motor assembly.

Thread lead wires and safety cable from 

motor assembly through downrod.

Mounting bracket

Canopy

Downrod

Keeper pin

Cross pin

Downrod

Yoke cover

Downrod Mount Installation

Canopy

Downrod

Downrod

Yoke cover

Yoke

Содержание 5LLR56

Страница 1: ...F PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com 5LLR56XXD Series Fan ETL Model NO 5LLR56 XXXXX 8 kgs 17 6 lbs 3 0 6 4 9 6 4 ...

Страница 2: ...o Not Remove Knockouts In The Outlet Box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building structure or the ceiling joist Attach the mounting bracket using only the hardware supplied with the outlet box WARNING To Reduce The Risk Of Electric Shock This Fan Must Be Installed With a general use isolating Wall Control Switch WARNING To red...

Страница 3: ...bs Use metal outlet box suitable for fan support and use only the screws provided with the outlet box must support 35 lbs Before attaching fan to outlet box ensure the outlet box is securely fastened by at least two points to a structural ceiling member a loose box will cause the fan to wobble Remove the two outlet box screws provided with the box aligning the holes of the mounting bracket with th...

Страница 4: ...ructure beams using 1 5 lag screws washers and lock washers provided Make sure that when the safety cable is fully extended the lead wires are longer than the cable and no stress is placed on the lead wires Note If Installing The Secondary Support Safety Cable in the U S Do Not Remove Knockouts In The Outlet Box Make wiring connections using wire connectors provided as indicated above Red from fan...

Страница 5: ...ne of non slotted holes on the rim of the canopy For Canadian installation and for USA fan and light kit combinations over 35 lbs in both flush and downrod modes the safety cable must be installed into the house structure beams using 1 5 lag screws washers and lock washers provided Make sure that when the safety cable is fully extended the lead wires are longer than the cable and no stress is plac...

Страница 6: ...ding to the slotted holes on the canopy upper ring Remove the other 2 set screws Save screws Raise canopy to mounting bracket aligning loosened screws in mounting bracket with slotted holes in canopy Twist canopy to lock Reinstall the screws removed in step 18 and tighten all screws securely Align the holes of blade bracket blade and the top plate of blade bracket Install blade bracket with blade ...

Страница 7: ...e wire from fan to blue wire from light fixture Attach light fixture onto the light plate aligning keyhole slots on the light fixture with the preassembled set screws on light plate and twist clockwise until lock Reinstall the screw removed in step 23 Tighten all screws securely Place glass over glass fixed ring aligning the thread on light fixture and attach it onto light fixture by turning clock...

Страница 8: ...mote control transmitter and install battery battery provided Replace the cover Note Use 2 1 5V AAA battery Note If not using for long period of time remove battery to prevent damage to remote transmitter and store the remote transmitter away from excess heat or humidity ON DIM LEARN L CODE COMMON CODE L CODE COMMON CODE ON DIM Universal Mold Learning Mold Dimming Non Dimming Setting The DIM selec...

Страница 9: ...leased Note This remote controller has auto resume function the fan and light will maintain the last setting if power is turned off Tips for end users 1 If your fan is operated automatically after installation and power on it is because your fan is still memorize the previous setting at factory 2 If fan or light isn t working reset power turn the power off for at least 10 seconds and then turn the...

Страница 10: ...N LQ SHULRG RI KRXUV 0RVW QRLVHV DVVRFLDWHG ZLWK D QHZ IDQ ZLOO GLVDSSHDU DIWHU WKLV SHULRG I WKLV LV D GRZQURG PRXQW IDQ PDNH VXUH WKH ULGJH RQ PRXQWLQJ EUDFNHW HQJDJHV WKH QRWFK LQ WKH GRZQURG EDOO 0DNH VXUH WKDW FDQRS PRXQWLQJ EUDFNHW RU PRXQWLQJ SODWH DUH WLJKWHQHG VHFXUHO WR FHLOLQJ MXQFWLRQ ER DQG MXQFWLRQ ER LV PRXQWHG UPO WR FHLOLQJ MRLVW KHFN WKDW DOO EODGHV DUH VFUHZHG UPO LQWR EODGH KRO...

Страница 11: ...Oct 2014 ...