background image

TOOls reQuIred

Phillips Screwdriver      Wire Cutters       Pliers      Step Ladder

Before you begin installing the fan, Switch

power off at Service panel and lock service dis-

connecting means to prevent power from being

switched on accidentally.  When the service dis-

connecting means cannot be locked, securely

fasten a prominent warning device, such as a

tag, to the service panel.

Before installing this fan make sure the outlet box is
properly installed to the house structure.  To reduce
the risk of fire, electric shock, or personal injury,
mount to outlet box or supporting system acceptable
for fan support. (Mounting must support at least 35
lbs.)

2

1

Installation

Use metal outlet box suitable for fan support
and use only the screws provided with the out-
let box (must support 35 lbs). Before attaching
fan to outlet box, ensure the outlet box is
securely fastened by at least two points to a
structural ceiling member ( a loose box will
cause the fan to wobble). 

use only the screws

provided with the outlet box.  

3

Remove the keeper pin and cross pin

from downrod, and save for later use

4

Place canopy over down rod.

5

6

Place Yoke Cover over down rod.

Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA 70-1999),

including fire-rated construction.

Use this unit only in the manner intended by the manufacturer.  If you have  any questions contact the manufacturer.

After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side

of the outlet box and ungrounded conductor on the other side of the outlet box. The splices, after being made, should be turned upward and

pushed carefully up into the outlet box.

warnInG

: Before you begin installing the fan, servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to

prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning

device, such as a tag, to the service panel.

Be cautious! read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the floor to

the trailing edge of the blade.

warnInG

: To reduce the risk of fire, electric shock, or personal injury, mount to outlet box marked “acceptable for fan support” and use mounting

screws provided with the outlet box  (Mounting must support at least 35 lbs.)

warnInG

: To reduce the risk of personal injury, do not bend blade holders during installation to motor, balancing or during cleaning.  Do not insert for-

eign object between rotating blades.

Attach the mounting bracket using only the hardware supplied with the outlet box.

warnInG

: To reduce the risk of fire or electric shock, this fan must be installed with an isolating wall control/switch.

warnInG

: To reduce the risk of fire or electric shock, this fan should only be used with fan speed control part no. UC7067RC manu-

factured by Rhine Electronic Co., Ltd. Suitable for use with solid-state speed controls.

NEVER place a switch where it can be reached from a tub or shower.

The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equipment man-

ufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating,

Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

cauTIOn: 

To Reduce the Risk of Electric Shock, Disconnect the electrical supply circuit to the fan before installing the light kit. 

All set screws must be checked and tightened where necessary before installation. 

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

warnInG: TO reduce The rIsK OF FIre, elecTrIc shOcK, Or InJury TO persOns,

OBserve The FOllOwInG: read and save These InsTrucTIOns

s

aFeTy

T

Ips

Содержание 5CXR52

Страница 1: ...Ceiling Fan Installation Instructions For 5cXr52XXd series Fans read and save These InsTrucTIOns Total fan weight with light kit Owner s Manual UL Model No 5CXR52...

Страница 2: ...ans cannot be locked securely fasten a prominent warning device such as a tag to the service panel Be cautious read all instructions and safety information before installing your new fan Review the ac...

Страница 3: ...er pin 10 Tighten the 2 set screws on the yoke once the down rod is in place 11 Hang assembled fan from the mounting bracket installed to ceiling in previous step Make sure the fan is hanging straight...

Страница 4: ...otor for shipping stabilizers and remove if present Attach blades using screws and fiber washers in hardware pack Tighten screws securely Repeat this procedure 4 more times 21 Loosen 2 screws and remo...

Страница 5: ...LL Attach front cover to wall control with screws provided Snap battery cover in place 34 Remove battery cover Install 12V battery into wall remote Duracell MN21 Eveready A23 GP 23A all 12V Attach cov...

Страница 6: ...mmer once quickly To turn off press once quickly while light is on To dim light hold down button light dimmer The light will cycle from bright to dim to bright until button is released Light will main...

Страница 7: ...e tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse the position of the washer if blades mount from top of blade 6 If blade wobble...

Страница 8: ...l utilisateur Instructions pour l installation d un ventilateur de plafond Por 5CXR52XXD Serie Ventilateurs LIRE ET GARDER CES INSTRUCTIONS Poids total du ventilateur et du kit d clairageht UL Model...

Страница 9: ...peuvent pas tre verrouill s apposer avec soin un dispositif d avertissement bien visible tel qu une tiquette sur le tableau lectrique 5 Prudence Lire toutes les instructions et conseils de s curit ava...

Страница 10: ...de 7 62 cm fournies cet effet Assurez vous que lorsque le c ble de s curit est enti re ment d pli les fils de connexion sont plus longs que le c ble et qu ils ne sont soumis aucun effort de tension 14...

Страница 11: ...l isateurs pour l exp dition les retirer si pr sents Fixer les pales l aide des vis et des joints en fibre dans le paquet pour la visserie Bien serrer les vis R p ter l op ration 4 fois 21 Desserrer 2...

Страница 12: ...31 L option sens inverse de ce ventilateur est contr l par un interrupteur situ sur le haut du bo tier du ventilateur Eteindre le ventilateur et inverser le sens du ventila teur en poussant l interrup...

Страница 13: ...serrez une fois rapidement tandis que la lumi re est allum e Pour obscurcir la lumi re maintenez le bouton grada teur l ger La lumi re fera un cycle de lumineux pour obscurcir lumineux jusqu ce que l...

Страница 14: ...or chaque pale Si certaines pales ne sont pas de niveau celui ci peut tre obtenu en appliquant la proc dure suivante Pour abaisser l extr mit d une pale introduire une rondelle non fournie entre la pa...

Отзывы: